106
10.3 Replacement steps
Front Service:
Module
Power off the cabinet where the module is in
Remove the module from front by front service tool as shown below
Remove the screws which connect the power-data cable into the bad module by short
screwdriver and then take off the bad module from cabinet by hand as shown below
Bring a new module and connect the power-data cable into the new module by short
screwdriver as shown below
Put the new module on the cabinet and then install it into cabinet by front service tool as
shown below
Power on the cabinet.
After replacing modules, the customer should update the calibration data for that module
in the receiving card. Operation details are shown below. All the spare module have a serial
number as S-1, S-2, S-3 etc.
Summary of Contents for XA010J
Page 3: ...3 10 1 Cleaning 104 10 2 Calibration 105 10 3 Replacement steps 106 11 Appendix 119 ...
Page 12: ...12 3 2 Product Appearance ...
Page 13: ...13 ...
Page 14: ...14 3 3 Product design Decomposition chart ...
Page 15: ...15 Assembly drawing ...
Page 16: ...16 3 4 Product main components Module Power Supply Receiving Card Monitoring Card ...
Page 17: ...17 Fan Hub board Power data cables 16pcs DC power cables 8PCS and Flat cables 16 pcs ...
Page 35: ...35 Installation of cabinets Fixing of connect plate ...
Page 42: ...42 8 2 Port of Cabinet and serial number paint ...
Page 59: ...59 ...
Page 68: ...68 ...