background image

 
 

#  tsWF520   RevB 03/21/2011                                                                                                                                                                   

 2 

 

CN8

 

CN7

 

CN6

 

CN10

 

CN1

 

CN3

 

CN6

 

CN2

 

RY

RY
11

 

RY
13

 

To MEMS 
connector 
on Main 
PCB CN11          

To MEMS 
connector 
on outer 
tub 

CN11

 

PNK 

BLU 
YEL 
RED 
VIO 
 

WHT 

ORG 

Door Ck Sw 

Thermistor 

CN7

 

Summary of Contents for WF520ABP/XAA

Page 1: ...t Code Test Press the Spin button to view the stored fault codes then turn Jog Dial to view error codes Push Start Pause while the code is displayed to view the number of cycles since the error occurr...

Page 2: ...tsWF520 RevB 03 21 2011 2 CN8 CN7 CN6 CN10 CN1 CN3 CN6 CN2 RY1 RY11 RY13 To MEMS connector on Main PCB CN11 To MEMS connector on outer tub CN11 PNK BLU YEL RED VIO WHT ORG Door Ck Sw Thermistor CN7...

Page 3: ...sp pcb Vio CN7 2 Rx Disp pcb S Blu CN7 3 Reset Signal Disp Pnk CN7 4 5vdc Brn CN7 5 DC Common Org CN7 6 15vdc Blk 7 Main Reset Yel 8 Water Level Blu 9 Watchdog Signal Wht Steam Heater Relay Check Test...

Page 4: ...VAC with the Valve off Power Off valve resistance is from 1202 1245 Error Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched dama...

Page 5: ...se of moisture If the main PCB s communication circuit is faulty replace it EEPROM Fault 11 Go to EEPROM Clear Mode If display shows FAiL Replace Ma chine Control Board Switch Error Main Relay Error E...

Page 6: ...sor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the...

Page 7: ...XER DC67 00307A HOSE HANGER DC62 10278A When using non HE detergents or using too much detergent for the water hard ness and soil level of the clothing over sudsing will occur When this happens there...