Error Type  

Error Mode  

Details  

LED LCD 

                             
Drain Error 

                         
nD                               

 

Check for Foreign material entering the pump or hoses.  

Check to make sure the wiring harness is connected properly. 

Check the water pump terminal . 

Check for freezing 

                         
Power Error  

                         
2E           
91           
92  

 

Make sure to check the operating voltage. (An error occurs when 
under or over voltage is supplied.)   Check whether a plug recepta-
cle is used. When the connecting wires are too small (extension 
cord use), a momentary low voltage may drop up to 10 V 

Main PBA fault (sometimes) 

PF 

 

Momentary Power Failure 

                                 
Communica-
tion Error 

AE 

 

Check the wire connections and terminal contacts between the sub 
and main PBAs. 

Check for disconnected wires. 

Check whether the sub PCB is short circuited because of moisture. 
If the main PCB’s communication circuit is faulty, replace it. 

                              
Switch Error 

(Main Relay 

Error)  

                         
E2           
15 

 

Check whether either the Power switch or a tact switch (any button)  
is stuck down. 

Check whether the service PBA holding screws are fastened too 
tight pinching the contacts 

If the main PBA switching IC on/off error has occurred, replace the 
main PBA. 

The “E2” error occurs if the main relay connections are incorrect. 
Check the connections. If there is no error in the connections, re-
place the main PBA  

                        
SR 

 

 

dS           
22 

(Before 

operation) 

 

Door Error 

dL           
18 

(During 

operation) 

 

 

LO            

(Unlock 

Fail) 

 

 

FL             

(Lock Fail) 

 

 

 

 

Check the door switch and latch alignment .  

Check the latch for damage 

Check the wiring harness to the latch.  

Check the door switch. Replace if faulty. 

Check the main PBA door sensing circuit. Replace if faulty. 

Finally verify he operation of the Main PCB 

EEPROM 
Fault. 

11 

 

Go to “EEPROM Clear Mode” If display shows “FAiL”, Replace Ma-
chine Control Board 

5