background image

Door Lock Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and CN10 Pin 7 (S/
Blue)

 

When Door is Locked or Unlocked 
there is a pulse of 120VAC for a few 
milliseconds.

 

With Power Off, the resistance  
between these pins will be between 
47 - 57

 

Door Unlock Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and CN10 Pin 8 
(White)

 

When Door is Locked or Unlocked 
there is a pulse of 120VAC for a few 
milliseconds.

 

With Power Off, the resistance  
between these pins will be          
between 47 - 57

 

Drain Motor Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and CN10 Pin 6 
(Black)

 

120VAC with the pump On and 0VAC 
with the pump off

 

Power Off, the resistance should be 
13.9

 

Water Valve Check

 

Test 1

 

Test 2

 

Connector CN7 Pin 2 (Black) to CN10 Pin 4 (Pink), 
Pin 2 (Red) , Pin 1 (Blue),

 

120VAC with the Valve On and 0VAC 
with the Valve off

 

Power Off, valve resistance is from 
1202

 - 1245

 

Heater Relay Check

 

Test 1

 

Test 2

 

Connector CN5 Pin 3 (Blue) and RY3 (heater re-
lay) Pin 2 (Red) (A/C Voltage Only)

 

120VAC with the Heater On and 0VAC 
with the Heater off

 

Power Off, heater resistance (at the 
heater) is  16.6 

 

Error Type  

Error Mode  

Details  

LED LCD 

                                                         
Water Level Sensor 

               
LE       

 

Check the Hose where the sensor is connected, may be loose, 
pinched, damaged or clogged. Also check the sensor it may be 
disconnected or defective. The Main PCB may also be defective  

                                                 
Motor Drive  Error or 
Hall Sensor error  

 

          
3E 

 

Check the  motor drive connector, it may be loose. The hall sensor 
may be disconnected, loose or damaged . Check for a foreign ob-
ject inside the motor or motor damage. The stator might be loose 
or damaged. The drum might be overloaded from too many 
clothes or the relay or PCB  might be defective.      

 

E3 

bE 

                                              
Water Supply 

Error 

                        
nF   

 

Check the water valve wiring harness. 

Check whether the water supply valve is clogged with foreign ma-
terial and whether water is supplied properly. 

Check for reversed fill hoses 

Check water temperature, if sensed as higher than 50 

˚

C in the 

Wool or Lingerie cycle it will create error. 

Check the relays, if they operate correctly replace the Main PCB. 

Fill Hoses Reversed  nF1 

 

Correct Hot/Cold hose connections 

System Error 

SF1 
SF2  
SF3 

 

Replace PCB

 

4