background image

 
 

#  tsWF203   RevD 03/21/2011                                                                                                                                                                   

 5 

 

Error Type  

Error Mode  

Details  

LED 

LCD 

                             
Drain Error 

                         
nD                               

 

Check for Foreign material entering the pump or hoses.  

Check to make sure the wiring harness is connected properly. 

Check the water pump terminal . 

Check for freezing 

                         
Power Error  

                         
2E           
91           
92  

 

Make sure to check the operating voltage. (An error occurs when 
under or over voltage is supplied.)   Check whether a plug recepta-
cle is used. When the connecting wires are too small (extension 
cord use), a momentary low voltage may drop up to 10 V 

Main PBA fault (sometimes) 

PF 

 

Momentary Power Failure 

                                 
Communica-
tion Error 

AE 

 

Check the wire connections and terminal contacts between the sub 
and main PBAs. 

Check for disconnected wires. 

Check whether the sub PCB is short circuited because of moisture. 
If the main PCB’s communication circuit is faulty, replace it. 

EEPROM 
Fault. 

11 

 

Go to ―EEPROM Clear Mode‖ If display shows ―FAiL‖, Replace Ma-
chine Control Board 

                              
Switch Error 

(Main Relay 

Error)  

                         
E2           
15 

 

Check whether either the Power switch or a tact switch (any button)  
is stuck down. 

Check whether the service PBA holding screws are fastened too 
tight pinching the contacts 

If the main PBA switching IC on/off error has occurred, replace the 
main PBA. 

The ―E2‖ error occurs if the main relay connections are incorrect. 
Check the connections. If there is no error in the connections, re-
place the main PBA  

                        
SR 

 

 

dS           
22 

(Before 

operation) 

 

 

 

 

Check the door switch and latch alignment .  

Check the latch for damage 

Check the wiring harness to the latch.  

Check the door switch. Replace if faulty. 

Check the main PBA door sensing circuit. Replace if faulty. 

Finally verify he operation of the Main PCB 

Door Error 

dL           
18 

(During 

operation) 

 

 

LO            

(Unlock 

Fail) 

 

 

FL             

(Lock Fail) 

 

Summary of Contents for WF203ANS/XAA

Page 1: ...es Push Start Pause while the code is displayed to view the number of cycles since the error occurred Peripheral Main PCB input Tests 1 Extra Wash Then turn the Dial so that the Normal is turned on Next press the Start Pause Key The Water Temperature will be displayed in Fahrenheit 2 Extra Wash Then turn the Dial so that the Whites is turned on Next press the Start Pause Key The door status will b...

Page 2: ... tsWF203 RevD 03 21 2011 2 WF203 ...

Page 3: ...C May indicate a connector issue 12kΩ 14kΩ Door Switch Check Test 1 Test 2 Connector CN3 pins 6 Org 4 Brn 5VDC Door Open 0VDC Door Closed Operating Resistance with power off open with door open short with door closed Water Level Sensor Check Test 1 Test 2 Voltage Connector CN 3 pins 6 Org 7 Vio And Connector CN 3 Pins 6 Org 8 Pnk Resistance Connector CN 3 Pin 8 Pink and CN7 Pin 7 Violet Operating ...

Page 4: ...e lay Pin 1 Red 120VAC with the Heater On and 0VAC with the Heater off Power Off heater resistance is 16 6 Ω Error Type Error Mode Details LED LCD Water Level Sensor LE 8 Check the Hose where the sensor is connected may be loose pinched damaged or clogged Also check the sensor it may be disconnected or defective The Main PCB may also be defective Motor Drive Error or Hall Sensor error 3E Check the...

Page 5: ...use of moisture If the main PCB s communication circuit is faulty replace it EEPROM Fault 11 Go to EEPROM Clear Mode If display shows FAiL Replace Ma chine Control Board Switch Error Main Relay Error E2 15 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switchin...

Page 6: ...ly Verify the water valves shut off fully Finally check the water level sensor Temperature Sensor Error 29 The washing heater temperature sensor in the tub has an error Check the connections for the washing heater temperature sensor connector Unbalance Error dC 10 Check the type of laundry Check whether it may cause an unbal anced situation Educate the consumer in this case to press pause repositi...

Page 7: ...etergent for the water hard ness and soil level of the clothing over sudsing will occur When this happens there will be leaks out of the detergent drawer and door Please advise con sumer of proper de tergent usage It is normal for a small amount of water remaining in Detergent Drawer after it completes washing Bleach is usually flushed out into the tub at the beginning of the washing Also its comp...

Reviews: