19
11. Natural Drain/Water Leak Error
- If more than 4 times of water supply and safe water level of Heater are sensed for each course, this
error will occur.
- Display : “LE
- This error will be released by turning off Power S/W.
12. Tacho Error
- If Motor Tacho is abnormal, this error will occur.
- If Tacho signals are inputted less than 2 for 2sec after Motor started, this error will occur.
- Display : “3E”
- This error will be released by turning off Power S/W.
13. Motor TRIAC Short Error
- If Tacho signals are inputted more than 300 every 1sec in the operational interval less than 90RPM,
this error will occur.
Turn off Power S/W at that time.
- Display : “bE”
- This error will be released by turning off Power S/W.
14. Thermistor Abnormal Error
- If Thermistor circuit is abnormal, this error will occur.
- If Thermistor is lower than 0.2V or higher than 4.5V, this error will occur.
- Display :”tE”
- This error will be released by turning off Power S/W.