6-2
6. TROUBLE DIAGNOSIS
No
Item
Cause and treatment
1
The power is not supplied
- Is the PCB connector connected well?
- Is the voltage normal?
- Is the power supply plug connected well?
- Is the noise
fi
lter connected well?
- Is the secondary output of the power su pply transformation normal?
- Is the fuse disconnected? (option)
If above points are not found, the PCB assembly is out of order. Replace it.
y
2
The water is not supplied.
- Is the knob open?
- Did you push START/PAUSE button after selecting the course?
- Is the water supply valve connected well?
- Is the winding of the water supply valve continuous?
- Is the connection and operation of the pressure switch normal?
If above points are not found, the PCB assembly is out of order. Replace it.
y
3
The wash does not start though the
water supply is stopped.
- Is the connection and operation of the pressure switch normal?
- Is the pressure switch hose damaged so that the air is leaked?
- Is the pressure switch hose bent?
- Check the operation of the water level switch.
If above points are not found, the PCB assembly is out of order. Replace it.
y
4
The drum does not rotate during
washing.
- Is the belt connected well?
- Is the winding of the motor continuous?
(Rotor winding, stator winding, generator)
- Is the motor protector normal?
If above points are not found, the PCB assembly is out of order. Replace it.
y
5
The drum rotates by one direction during
washing. (The drum rotates to one
direction for SPIN.)
- The PCB assembly is out of order. Replace it.
(Inversion relay open trouble)
6
Drainage problem.
- Is the drainage hose bent?
- Is the winding of the drainage pump continuous?
- Is the drain
fi
lter clogged by the waste?
If above points are not found, the PCB assembly is out of order. Replace it.
y
7
Dehydration problem.
- The unbalance is detected.
- Put in the laundry uniformly and start again.
8
Abnormal noise during SPIN.
- Is the pulley nut loosen?
- Is the transport safety device removed?
- Is the product installed on the level and stable place?
(Little noise may be generated during the high-speed SPIN.)
9
Leak breaker or current/leak breaker is
down during washing.
<When the leak breaker and current breaker is installed separately>
- When the leak breaker is down, check and make the earth of the outlet.
- When the current is down, the current is leaked.
<Is the breaker down when the leak/current breaker is combined?>
- Check the rated capacity of the current and leak breaker.
The current breaker may be down due to the lack of the current when the
wash machine and other apparatus are used.
In this case, execute the cold water wash to check whether the current
capacity is lack.
10
The heating is not executed.
- Is the wash heater terminal unplugged?
- Is the wash heater normal?
If above points are not found, the PCB assembly is out of order. Replace it.
y
Summary of Contents for WF-F125AV
Page 1: ...9 1 9 BLOCK DIAGRAM ...
Page 2: ...9 2 9 BLOCK DIAGRAM Memo ...
Page 6: ...13 1 13 CIRCUIT DESCRIPTIONS 13 1 OVERALL SYSTEM DIAGRAM ...
Page 23: ...7 3 7 EXPLODED VIEWS AND PARTS LIST Memo ...
Page 28: ...7 8 7 EXPLODED VIEWS AND PARTS LIST Memo ...
Page 64: ...10 SCHEMATIC DIAGRAM 10 1 10 SCHEMATIC DIAGRAM 10 1 EMZ NOT USE IN THIS MODEL ...
Page 65: ...10 SCHEMATIC DIAGRAM 10 2 10 2 ROLD WF7452S9R C WF7450S9C ...
Page 74: ...10 SCHEMATIC DIAGRAM 10 1 10 SCHEMATIC DIAGRAM 10 1 EMZ NOT USE IN THIS MODEL ...
Page 75: ...10 SCHEMATIC DIAGRAM 10 2 10 2 ROLD WF7452S9R C WF7450S9C ...
Page 78: ...7 3 7 EXPLODED VIEWS AND PARTS LIST Memo ...