5-5
5. ASSEMBLY AND DISASSEMBLY
Part Name
Descriptive Picture
How To Do
Water Level
Sensor
1. Remove the top cover.
2. Remove the fixing screws for the water level
sensor.
3. Disconnect the water level sensor harness.
4. Disconnect the hose pressure.
5. Replace the water level sensor.
Door-Hinge
1. Remove the fixing screws holding the Door-Glass.
2. Separate the glass.
3. Remove the screws holding the bracket holder
4. After removing the two screws holding the Holder
Glass, replace the Door Hinge.
5. After putting them back together, check if the
screws holding the Door Hinge is fastened
properly.