30
Webthru SWC 306 User’s Guide
Audio Device
This protocol is for Webthru Audio device, which is an audio transmission device connected to Webthru.
11) Digital I/O Configuration
This page is to configure digital input
state and control script. Webthru sends
e-mails or/and files when connected
external sensors detect events.
(1) Input Port 1, 2, 3, 4, 5, and 6
Administrator defines active state of 6
digital devices connected to six input
ports such as infrared sensors. If normal
open type device is connected to input
port, select ‘NO (Normally Open)’.
With normal close type device, select
‘NC (Normally Close)’.
(2) Output Port 1, 2, 3, 4, 5, and 6
Webthru shows current states of the 6
digital devices connected to 6 output
ports. In the status panel, active state or
de-active state message shows. ‘De-
Active State’ means that connected
device didn’t detect any event when ‘Apply’ button is clicked. Though this message is not updated until
‘Apply’ button is clicked again, Webthru keeps on receiving status information from the connected device.
12) Alarm Configuration
This page is to set image- recording
conditions during an event situation for
e-mail/FTP delivered images.
(1) Motion Detection Threshold
Administrator sets the threshold for
motion detection function. Threshold
‘0’ is the most sensitive state and ‘900’
is the least sensitive state.
(2) Alarm Parameters for E-mail /
FTP Application
Administrator defines the image-
recording conditions for an event, if Webthru detects events through motion detection function (MD Event) or
external devices (SID1, SID2, SID3, SID4, SID5 and SID6).
13) User Custom Configuration