Samsung WA484DSHASU/A1 Fast Track Troubleshooting Download Page 4

 
 

#  nwWA484 09/21/2013 

               

 

Error Type  

Error Mode  

Details  

LED  

                             

Drain Error 

 nd                                

Check for Foreign material entering the pump or hoses.  

Check to make sure the wiring harness is connected properly. 

Check the water pump terminal . 

Check for freezing. 

The water level fails to drop below the Reset Water Level

 

  within 30 minutes. 

                         

Power Error  

   2E             

Make sure to check the operating voltage. (An error occurs when 
under or over voltage is supplied.)   Check whether a plug recepta-
cle is used. When the connecting wires are too small (extension 
cord use), a momentary low voltage may drop up to 10 V 

Main PBA fault (sometimes) 

PF  

Momentary Power Failure 

                                 

Communica-

tion Error 

AE  

Check the wire connections and terminal contacts between the sub 
and main PBAs. 

Check for disconnected wires. 

Check whether the sub PCB is short circuited because of moisture. 
If the main PCB’s communication circuit is faulty, replace it. 

                              

Switch Error 

(Main Relay 

Error)  

  E2             

Check whether either the Power switch or a tact switch (any button)  
is stuck down. 

Check whether the service PBA holding screws are fastened too 
tight pinching the contacts 

If the main PBA switching IC on/off error has occurred, replace the 
main PBA. 

The “E2” error occurs if the main relay connections are incorrect. 
Check the connections. If there is no error in the connections, re-
place the main PBA  

  SR  

Door Error 

ds          

(Before 

operation)  

 

 

 

Check the door switch and latch alignment .  

Check the latch for damage 

Check the wiring harness to the latch.  

Check the door switch. Replace if faulty. 

Check the main PBA door sensing circuit. Replace if faulty. 

Finally verify he operation of the Main PCB 

Failed Lock 

FL 

(Lock Fail)  

Unlock Failure  

LO             

(Unlock 

Fail)                

  

Summary of Contents for WA484DSHASU/A1

Page 1: ...he stored fault codes then turn Jog Dial to view error codes Push Start Pause while the code is displayed to view the num ber of cycles since the error occurred Peripheral Main PCB input Tests 1 Select Extra Rinse Then turn the Jog Dial so that the Normal LED is turned on The Water Temperature will be displayed in Centigrade 2 Select Extra Rinse Then turn the Jog Dial so that the Heavy Duty is tur...

Page 2: ...erminals Power Off 2 kΩ across CN4 PIN 8 Brn and CN6 PIN 3 Blk Violet Black Brown 0Ω Violet Black Black 2KΩ Brown Black 2KΩ Test 1 Test 2 Pin 3 BLK of CN6 and Pin 7 YEL of CN4 120VAC with the Mtr On and 0VAC Off Resistance Pin 3 BLK of CN6 to Pin 7 YEL of CN4 20Ω CN8 1 Motor Pwr U Phase Red 2 Motor Pwr V Phase Wht 3 Motor Pwr W Phase Blu RY12 Relay 1 AC Line out WHT 2 AC Line BLK CN7 1 Reactor Con...

Page 3: ...ED Water Level Sensor LE 8 Check for water to the valves clogged valve screens defective valve solenoid coils Check the water level pressure sensor Check for 120VAC to the valve Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign ob ject inside the motor or motor damage The stator might b...

Page 4: ...Check for disconnected wires Check whether the sub PCB is short circuited because of moisture If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error ...

Page 5: ...nd complete the wash cycle Mems or Har ness Failure 8E Check MEMS PCB Main PCB Wire harness MEMS sensor error If the output from the MEMS sensor is over 4 5VDC open or below 0 5VDC shorted for 5 seconds this error will occur Foaming Detected SUdS Sd This occurs when too much foaming is detected It is also displayed while foaming is removed When the removal is finished the normal cycle proceeds Thi...

Page 6: ...2013 HOT COLD BLEACH RINSE CLUTCH Softener is dispensed in the final rinse by the RINSE valve This valve is only used to dispense the Soften Door locked by Reed Switch in blue plastic Door Lock Replaced as an Assembly ...

Page 7: ... nwWA484 09 21 2013 ...