Samsung WA484DSHASU/A1 Fast Track Troubleshooting Download Page 3

 
 

#  nwWA484 09/21/2013 

               

 

Door Lock Check

 

Test 1

 

Test 2

 

Resistance check CN3 Pin #5 (Red) and Pin #7 
(Wht) 

Power Off, resistance is Approx 
0.2 

 

Motor resistance at CN3  

Pins 1-2 (Blk-Brn) 40K

 

Door Unlock Check

 

 

Test 2

 

Resistance check CN3 Pin #4 (Blu) and Pin #7 
(Wht) 

Power Off, resistance is Approx 
0.2 

 

Motor resistance at CN3  

Pins 1-2 (Blk-Brn) 40K

 

Drain Motor Check

 

Test 1

 

Test 2

 

Voltage at Pin #1 of RY12 (WHT) and Pin #9 
(PNK) of CN4 
 

120VAC with the pump On and 0VAC 
with the pump off

 

Voltage at Pin #1 of RY12 (WHT) 
and Pin #9 (PNK) of CN4 
should be ~14

 

Water Valve Check

 

Test 1

 

Test 2

 

Voltage at Pin #3 (BLK) of CN6 to Pin #2 (GRY) of 
CN4 Bleach Valve, Pin #3 (BLU) of CN4 Cold 
Valve, Pin #4 (RED) of CN4 Hot Valve, Pin #5 
(WHT) of CN4 Rinse Valve 
 

120VAC with the Valve On and 0VAC 
with the Valve off

 

Power Off, valve resistance is from 
1202

 - 1245

 

Error Type  

Error Mode  

Details  

LED  

Water Level Sensor 

   LE 

    8              

    Check for water to the valves, clogged

 

valve screens, defective valve 

solenoid

 

coils.  Check the water level / pressure

 

sensor

 

Check for 120VAC 

to the valve.

 

                                                 

Motor Drive  Error or 

Hall Sensor error  

 

          3E  

Check the  motor drive connector, it may be loose. The hall sensor 
may be disconnected, loose or damaged . Check for a foreign ob-
ject inside the motor or motor damage. The stator might be loose 
or damaged. The drum might be overloaded from too many clothes 
or the relay or PCB  might be defective.      

 

E3 

 

 

                                              

Water Supply 

Error 

                        nF   3 

 

Check the water valve wiring harness. 

Check whether the water supply valve is clogged with foreign ma-
terial and whether water is supplied properly. 

Check for reversed fill hoses 

Check water temperature, if sensed as higher than 50 

˚

C in the 

Wool or Lingerie cycle it will create error. 

Check the relays, if they operate correctly replace the Main PCB. 

Fill Hoses Reversed 

nF1 

 

Correct Hot/Cold hose connections 

Cir. Pump Check 

Resistance check CN6 Pin #3 (Blk) CN4 Pin #7 (Yel)        Power Off, pump resistance is 20 

               N/A 

Summary of Contents for WA484DSHASU/A1

Page 1: ...he stored fault codes then turn Jog Dial to view error codes Push Start Pause while the code is displayed to view the num ber of cycles since the error occurred Peripheral Main PCB input Tests 1 Select Extra Rinse Then turn the Jog Dial so that the Normal LED is turned on The Water Temperature will be displayed in Centigrade 2 Select Extra Rinse Then turn the Jog Dial so that the Heavy Duty is tur...

Page 2: ...erminals Power Off 2 kΩ across CN4 PIN 8 Brn and CN6 PIN 3 Blk Violet Black Brown 0Ω Violet Black Black 2KΩ Brown Black 2KΩ Test 1 Test 2 Pin 3 BLK of CN6 and Pin 7 YEL of CN4 120VAC with the Mtr On and 0VAC Off Resistance Pin 3 BLK of CN6 to Pin 7 YEL of CN4 20Ω CN8 1 Motor Pwr U Phase Red 2 Motor Pwr V Phase Wht 3 Motor Pwr W Phase Blu RY12 Relay 1 AC Line out WHT 2 AC Line BLK CN7 1 Reactor Con...

Page 3: ...ED Water Level Sensor LE 8 Check for water to the valves clogged valve screens defective valve solenoid coils Check the water level pressure sensor Check for 120VAC to the valve Motor Drive Error or Hall Sensor error 3E Check the motor drive connector it may be loose The hall sensor may be disconnected loose or damaged Check for a foreign ob ject inside the motor or motor damage The stator might b...

Page 4: ...Check for disconnected wires Check whether the sub PCB is short circuited because of moisture If the main PCB s communication circuit is faulty replace it Switch Error Main Relay Error E2 Check whether either the Power switch or a tact switch any button is stuck down Check whether the service PBA holding screws are fastened too tight pinching the contacts If the main PBA switching IC on off error ...

Page 5: ...nd complete the wash cycle Mems or Har ness Failure 8E Check MEMS PCB Main PCB Wire harness MEMS sensor error If the output from the MEMS sensor is over 4 5VDC open or below 0 5VDC shorted for 5 seconds this error will occur Foaming Detected SUdS Sd This occurs when too much foaming is detected It is also displayed while foaming is removed When the removal is finished the normal cycle proceeds Thi...

Page 6: ...2013 HOT COLD BLEACH RINSE CLUTCH Softener is dispensed in the final rinse by the RINSE valve This valve is only used to dispense the Soften Door locked by Reed Switch in blue plastic Door Lock Replaced as an Assembly ...

Page 7: ... nwWA484 09 21 2013 ...

Reviews: