6.
Adjustment
6. Adjustment
6.1. Basic guide for adjustment
NOTE
•
After you replace remove this word electronic parts, you must make changes for each adjustment item in the
PL120
.
•
The following table shows the necessary adjustment item for replacing each part.
1) After replacing an electronic part, you must make adjustments for each item by referring to the following table.
Table 6.1
Adjustment
MAIN PCB
POWER PCB
BARREL ASSY
CCD ASSY
FIRMWARE UPGRADE
●
●
PUNT ADJ
●
●
●
BACKLASH
●
●
SHUTTER CLOSE TIME, IRIS ADJ,
CCD GAIN, LENS SHADING
●
●
●
FLASH ADJ
●
●
●
●
BATTERY LEVEL ADJ
●
●
BURNING TEST & CCD DEFECT
CELL
●
●
●
●
SERIAL NUMBER WRITING
●
2) Adjustment equipment
•
AE TESTER: AE TESTER that enables
LV 12
•
Infinity Callimator for PUNT adjustment
•
Gray chart (18%) for FLASH & AWB, DARK BOX
•
POWER SUPPLY: 4.2V/2A
3) Adjustment program file
Save and use the program for each adjustment item on the microSD card to adjust each item.
The file name for each adjustment item is the same as
“PL120_ADJ.TXT”
,
“PL121_ADJ.TXT”
.
Copyright© 1995-2011 SAMSUNG. All rights reserved.