WARNING
An electrolytic capacitor installed with the wrong polarity might explode.
CAUTION
Before servicing units covered by this service manual, read and follow the Safety Precautions section of
this manual.
NOTE
If unforeseen circumstances create conflict between the following servicing precautions and any of the
safety precautions, always follow the safety precautions.
1-2-1. General Servicing Precautions
Always unplug the unit’s AC power cord from the AC power source and disconnect the DC Power Jack before
1.
attempting to: (a) remove or reinstall any component or assembly, (b) disconnect PCB plugs or connectors, (c) connect
a test component in parallel with an electrolytic capacitor.
Some components are raised above the printed circuit board for safety. An insulation tube or tape is sometimes used.
2.
The internal wiring is sometimes clamped to prevent contact with thermally hot components. Reinstall all such elements
to their original position.
After servicing, always check that the screws, components and wiring have been correctly reinstalled. Make sure that
3.
the area around the serviced part has not been damaged.
Check the insulation between the blades of the AC plug and accessible conductive parts (examples: metal panels, input
4.
terminals and earphone jacks).
Insulation Checking Procedure: Disconnect the power cord from the AC source and turn the power switch ON. Connect
5.
an insulation resistance meter (500 V) to theblades of the AC plug. The insulation resistance between each blade of the
AC plug and accessible conductive parts (see above) should be greater than 1 megohm.
Always connect a test instrument’s ground lead to the instrument chassis ground before connecting the positive lead;
6.
always remove the instrument’s ground lead last.
1-3
1. Precautions
1-2. Servicing Precautions
Summary of Contents for UN40HU6900F
Page 31: ...Waveforms 1 HDMI input RX_Data RX_Clk 2 LVDS output 4 9 4 Troubleshooting ...
Page 34: ...Waveforms 1 CVBS OUT Grey Bar 2 LVDS output 4 12 4 Troubleshooting ...
Page 37: ...Waveforms 1 LVDS output 2 CH_CLK CH_VALID 2 CH_CLK CH_VALID 4 15 4 Troubleshooting ...
Page 40: ...Waveforms 1 CVBS OUT Grey Bar 2 LVDS output 4 18 4 Troubleshooting ...
Page 64: ...Factory Menu Name Data Range G10_Gain B10_Gain 4 42 4 Troubleshooting ...
Page 77: ...5 1 5 Wiring Diagram 5 Wiring Diagram 5 1 Wiring Diagram ...