Samsung Electronics
2-3
2-3 Refrigerating Cycle Block Diagram
Refrigerating cycle temperature and pressure
STD Pressure
Piping Temp.(°C)
Temp. Condition (°C)
Operating Condition
(kg/cm
2
G)
T1
T2
Indoor
Outdoor
3-way valve
DB
WB
DB
WB
Standard
5.0~5.2
11
11
27
19
35
24
A or B
Max over load
6.0~6.3
16
15
32
23
43
26
Cooling
Low temp.
3.4~3.6
3
2
21
15
21
15
Standard
5.0~5.2
12
10
27
19
35
24
A + B
Max over load
6.0~6.3
16
15
32
23
43
26
Low temp.
3.4~3.6
3
2
21
15
21
15
INDOOR UNIT
T1
T2
Gas side
Cooling
Compressor-A
Gas leak
check point
Liquid side
Capillary tube
2-way valve
3-way valve
Heat
exchanger
(Evaporator)
Heat
exchanger
(Condenser)
(A)
(B)
OUTDOOR UNIT