background image

ANNEX A. System Specifications 

A-2

 

© SAMSUNG Electronics Co., Ltd. 

(Continued) 

Item 

Specification 

Regulatory & Safety Compliance 

- KCC Type Approval/EMC Registration 

- IEC 60950-1/EN 60950-1/UL 60950-1 

- EN 55022/EN 55024/EN 61003-3-2/ 

EN 61003-3-3 

- FCC Part 15 Class A 

- FCC Part 68 

 

Summary of Contents for Ubigate iBG1003

Page 1: ......

Page 2: ...any and product names may be trademarks of the respective companies with which they are associated This manual should be read before the installation and operation and the operator should correctly in...

Page 3: ...rovide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not ins...

Page 4: ...the bottom of the chassis The label contains Product Identifier Number FCC Registration Number Ringer Equivalence Number REN NOTE If requested this information must be provided to your telephone comp...

Page 5: ...d or jacks used must comply with the FCC Part 68 rules CIRCUIT TYPE MODULE TYPE FACILITY INTERFACE CODE NETWORK JACK LOOP START LINE FXO T1E1 02LS2 04DU9 DN 04DU9 1KN 04DU9 1SN 04DU9 1SN PRI RJ11C RJ4...

Page 6: ...fect the operation of the equipment If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service Service Center...

Page 7: ...the Public Switched Telephone Network PSTN Answered by the called station Answered by the attendant Routed to a recorded announcement that can be administered by the Customer Premises Equipment CPE u...

Page 8: ...may be required from the American Society of Composers Authors and Publishers ASCAP or other similar organizations if copyright music is transmitted through the Music on Hold feature SAMSUNG ELECTRON...

Page 9: ...ork connection Energy Hazard careful treatment is needed Every wire for communication should be larger than 26 AWG Double pole neutral fusing Underwriters Laboratories The Ubigate iBG1003 system has b...

Page 10: ...ne Network Voltage TNV circuits found in WAN ports This equipment must be installed and maintained by properly trained service personnel Make sure the proper electrical service is available before plu...

Page 11: ...p or ankle strap and verify that it is in direct contact with your skin Avoid contact between the component and your clothing as it causes ESD damage 2 When handling any component that is removed from...

Page 12: ...GENERAL USER INFORMATION X SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 13: ...s composed of five Chapters and two Annexes CHAPTER 1 Ubigate iBG1003 Overview Describes Ubigate iBG1003 characteristics CHAPTER 2 Pre Installation Requirements Describes the safety regulation and how...

Page 14: ...ughly understood Such information may or may not be enclosed in a rectangular box separating it from the main text but is always preceded by an icon and or a bold title WARNING Provides information or...

Page 15: ...d Technical Support For questions regarding the product and technical supports http www samsungnetwork com Revision History EDITION DATE OF ISSUE REMARKS 00 04 2009 First Edition 01 06 2009 Modified v...

Page 16: ...INTRODUCTION XIV SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 17: ...Concerns section is to ensure the safety of users and prevent property damage Please read this document carefully for proper use Symbols Caution Indication of a general caution Restriction Indication...

Page 18: ...ge The power plug of iBG1004 system should be connected to an outlet with a protective ground When handling Ubigate iBG1003 components wear grounding wrist straps to avoid ESD damage to the card To av...

Page 19: ...rs on a desktop Practice good safety habits Use two people to mount the Ubigate iBG1003 into a rack This equipment must be installed and maintained by properly trained service personnel Make sure the...

Page 20: ...SAFETY CONCERNS XVIII SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 21: ...ment or Facilities IV Service Center IV Field Repairs IV General V Direct Inward Dialing DID V Equal Access Requirements V Electrical Safety Advisory VI Music on Hold Warning VI Direct Inward System A...

Page 22: ...Clock 1 6 CHAPTER 2 Pre Installation Requirements 2 1 General Site Requirements 2 1 Site Preparation 2 1 Environment 2 2 Inspecting the Ubigate iBG1003 2 3 Required Tools and Materials 2 4 Cables 2 4...

Page 23: ...ini Module 5 2 ATOI 1 1 Port ADSL over ISDN Mini Module 5 3 LMF 4M 4 Port Fast Ethernet Mini Module 5 5 Installing Mini Modules 5 6 Port Numbering 5 8 iBG1003 Port Numbering 5 9 ANNEX A System Specifi...

Page 24: ...e 4 6 Connecting 50 pin Champ Connector Port 4 7 Figure 4 7 Connecting a PRI Cable 4 8 Figure 4 8 AC Power Connection 4 9 Figure 5 1 ATOP 1 Mini Module 5 2 Figure 5 2 Connecting the ATOP 1 Mini Module...

Page 25: ...router It is a desktop unit and has four T1 E1 ports and two Ethernet ports by default Depending on the sub models it has two sets of voice ports consisting of FXO FXS and T1 E1 PRI ports to provide...

Page 26: ...in figure below Figure 1 1 Ubigate iBG1003 Front View Proper LED status is shown in the following table LED Indication Color Description Power Solid blue Power supply installed and operating normally...

Page 27: ...on P0 P3 T1 E1 Solid green T1 E1 port is operating normally Solid red T1 E1 port cable is not connected properly or critical alarm detected Amber User alarm detected Off System is not operating normal...

Page 28: ...r Mini module slot An optional ADSL module can be plugged into this slot Voice option module slot A voice option module can be plugged into this slot One is pre assembled in the factory in order to me...

Page 29: ...I 1 1 port ADSL over ISDN mini module LMF 4M 4 port Fast Ethernet switch mini module Internal Option Modules Currently no IOM is supported IOMs will be released in the future Voice Option Modules Ubig...

Page 30: ...the air goes through the system out to the right side On both sides there are grids of holes where air comes in and goes out When installing Ubigate iBG1003 ensure to make room around the system in or...

Page 31: ...tions General Site Requirements Site Preparation This section describes how to prepare your site for installation of the Ubigate iBG1003 router Ensure that the site is properly prepared before you sta...

Page 32: ...e rack For the cooling system to function properly the airflow around the chassis must be unrestricted For a service personnel to remove and install hardware components there must be adequate space at...

Page 33: ...ipment Verify the parts received against the list Your package contains the following items Ubigate iBG1003 Router Console cable DB 9 to RJ 45 cable adapter One UTP Ethernet cable Rack mount package o...

Page 34: ...s see Annex B Console port cable for a terminal connection Ethernet 10 100Base T CAT 5 UTP cable for a LAN connection Tools To unpack the router and prepare for installation you need the following too...

Page 35: ...k mounted unit Read Installation Safety Guidelines and Warnings before you start installing the router Desktop Installation For installing chassis you must secure unrestricted airflow for chassis cool...

Page 36: ...nstalling the router on a rack you need to attach brackets to the router The brackets can be ordered separately Attach the mounting brackets to the router as shown in figure below using the 4 of M4xL8...

Page 37: ...with the rack Figure 3 2 Rack Mounting the Router Grounding the Ubigate iBG1003 You must connect the chassis to a reliable earth ground as shown in below figure Verify the following The grounding cabl...

Page 38: ...CHAPTER 3 Ubigate iBG1003 Installation 3 4 SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 39: ...wrist straps to avoid ESD damage to the equipment Do not directly touch the backplane with your hand or any metal tool or you could shock yourself Connecting the Ubigate iBG1003 This section describe...

Page 40: ...Ubigate iBG1003 One RJ 45 to DB 9 adapter cable is provided with the router To connect the console cable 1 Plug the RJ 45 end of the cable into the console port on the Ubigate iBG1003 as shown in belo...

Page 41: ...gory 5 minimum Ethernet cable with RJ 45 connectors to connect to the network via an Ethernet port 1 Plug one end of the Ethernet cable into the appropriate Ethernet port on the target router Figure 4...

Page 42: ...ports for data and two optional T1 E1 ports for voice To connect a T 1E1 cable 1 Plug one end of the T1 E1 cable into an appropriate T1 E1 port on the target router Figure 4 3 Connecting T1 E1 Cable 2...

Page 43: ...tion lines or FXS DID lines from a Central Office of the Public Switched Telephone Network PSTN To connect an FXO cable Figure 4 4 Connecting FXO Cable 1 Plug one end of the FXO cable into an appropri...

Page 44: ...hich connect with Plain Old Telephone Services POTS telephones To connect an FXS cable Figure 4 5 Connecting an FXS Cable 1 Plug one end of the FXS cable into an appropriate FXS port on the target rou...

Page 45: ...Port The Ubigate iBG1003 has a 50 pin Champ connector port to support eight or sixteen FXS ports depending on sub modles The port is connected as shown below Figure 4 6 Connecting 50 pin Champ Connect...

Page 46: ...module provide 2 T1 ports running at 1 544 Mbps and supporting 24 voice timeslots or 2 E1 ports running at 2 048 Mbps and supporting 30 voice timeslots To connect a cable 1 Plug one end of the cable i...

Page 47: ...ord to the router 1 Connect the AC power connector to the power supply 2 Connect the other end to a grounded power receptacle rated for the Ubigate iBG1003 Figure 4 8 AC Power Connection External grou...

Page 48: ...he Ubigate iBG1003 is connected to a power source 2 Switch the rocker switch on the Ubigate iBG1003 back panel to the on position I Then the fan starts the LEDs start to blink in different colors and...

Page 49: ...stalling the option modules General Maintenance Guidelines Keep all Ubigate iBG1003 option modules dry and dust free and store them in electrical equipment friendly environments Mini Module Overview U...

Page 50: ...Description LINK GREEN Link is connected Blinking Green Link is not connected OFF Port is not connected ACT GREEN Transmit Receive is OFF Blinking Green Transmit Receive is ON OFF Port is not connecte...

Page 51: ...rovides an ADSL interface connecting to the Central Office through an ISDN line Figure 5 3 ATOI 1 Mini Module ADSL Port LEDs LED Indication Color Description LINK GREEN Link is connected Blinking Gree...

Page 52: ...The ADSL port should be connected with ISDN network However the Ethernet port is for use in other iBG models Therefore the Ethernet port should not be connected to any other device or port Figure 5 4...

Page 53: ...ng table explains the LEDs states in detail LED Indication Color Description Link Solid Green Link is established with speed 10 100 Mbps Off Link failure or no connection Activity Blinking Orange Blin...

Page 54: ...nents wear grounding wrist straps to avoid ESD damage to the equipment Do not directly touch the backplane with your hand or any metal tool or you could shock yourself To add a mini module 1 Loosen th...

Page 55: ...To remove an existing mini module 1 Loosen the 2 retention screws on the back module panel 2 Pull the module out of the slot In case if the slot has to remain empty cover the hole with a slot cover b...

Page 56: ...ext slot number based on the lower rows last left most numbered slot The main board is considered as network module slot 0 Mini modules are numbered from right to left starting with slot number zero I...

Page 57: ...E1 ports are numbered 0 0 0 1 0 2 and 0 3 starting from right to left Figure 5 9 iBG1003 Port Numbering iBG1003 s voice option modules are considered to consist of two mini modules according to the i...

Page 58: ...CHAPTER 5 Option Module Installation 5 10 SAMSUNG Electronics Co Ltd This page is intentionally left blank...

Page 59: ...ormal operation only Samsung certified u SD should be used Boot Flash Memory 2 MB AC Power Supply Input Voltage 100 240 V Frequency 50 60 Hz Power Consumption 72 W Temperature Operating High 113 F 45...

Page 60: ...2 SAMSUNG Electronics Co Ltd Continued Item Specification Regulatory Safety Compliance KCC Type Approval EMC Registration IEC 60950 1 EN 60950 1 UL 60950 1 EN 55022 EN 55024 EN 61003 3 2 EN 61003 3 3...

Page 61: ...1989 ANSI T1 403 1989 Input signal DSX 1 0 to 24 dB Output signal build out 0 7 5 dB 5 dB Equalization 0 to 655 ft DSX 1 Impedance 100 Connectors RJ 48C Timing Internal or network Pulse density AT T T...

Page 62: ...ANNEX A System Specifications A 4 SAMSUNG Electronics Co Ltd Ethernet Interface Item Specification Data flow Full duplex or half duplex Connectors RJ 45 Data speed 10 100 Mbps auto negotiating...

Page 63: ...ble Shape Figure B 1 Console Port Cable Cable Signaling and Pinout Console Port DTE RJ 45 to RJ 45 Rollover Cable RJ 45 to DB 9 Terminal Adapter connected to Rollover Cable Console Device Signal RJ 45...

Page 64: ...ight Through Wiring both ends are the same 10 100 1000 Base T interfaces Figure B 2 Ethernet LAN Interface Cable Cable Signaling and Pinout RJ45 Pin Wire Color T568A 1000Base T Signal 1 White Green BI...

Page 65: ...d 04 SAMSUNG Electronics Co Ltd B 3 T1 E1 Cable Cable Shape RJ 48C to RJ 48C Cable Figure B 3 T1 E1 WAN Interface Cable Cable Signaling and Pinout Pin Signal Pin Signal 1 RXRING 4 TXRING 2 RXTIP 5 TXT...

Page 66: ...tandard Straight Through Wiring both ends are the same 10 100Base T interfaces Figure B 4 LMF 4M Port Cable Cable Signaling and Pinout RJ45 Pin Wire Color T568A 1000Base T Signal 1 White Green BI_DA 2...

Page 67: ...l Ed 04 SAMSUNG Electronics Co Ltd B 5 ATOP 1 ATOI 1 Port Cable Cable Shape Figure B 5 ATOP 1 ATOI 1 Port Cable Cable Signaling and Pinout RJ 11 connector RJ 11 connector Pin Signal Signal Pin 1 1 2 2...

Page 68: ...Right Signal name 1 26 1 26 TIP 1 RING 1 14 39 14 39 TIP 14 RING 14 2 27 2 27 TIP 2 RING 2 15 40 15 40 TIP 15 RING 15 3 28 3 28 TIP 3 RING 3 16 41 16 41 TIP 16 RING 16 4 29 4 29 TIP 4 RING 4 17 42 17...

Page 69: ...Manual Ed 04 SAMSUNG Electronics Co Ltd B 7 Continued RJ 21 Left RJ 21 Right Signal name RJ 21 Left RJ 21 Right Signal name 11 36 11 36 TIP 11 RING 11 24 49 24 49 12 37 12 37 TIP 12 RING 12 25 50 25 5...

Page 70: ...ations B 8 SAMSUNG Electronics Co Ltd FXO FXS Port Cable Cable Shape Figure B 7 FXO FXS Port Cable Cable Signaling and Pinout RJ 11 connector RJ 11 connector Pin Signal Signal Pin 1 1 2 2 3 Ring Ring...

Page 71: ...not be mixed with other commercial wastes for disposal BATTERY SYMBOL INFORMATION Correct disposal of batteries in this product Applicable in the European Union and other European countries with sepa...

Page 72: ......

Reviews: