Install Manual
28
3.3
Using input/output terminals
3.3.1 Handling cable ends
The following details how to handle cables for the terminal block. Please note that different
gauges of wire are needed for stranded wire and solid wire.
- Stranded wire: Strip 8 ~ 10
㎜
of insulation off the end of the wire and solder it together. Use
AWG 22 ~ 26 wire.
- Solid wire: Strip 8 ~ 10
㎜
of insulation off the end of the wire. Use AWG 20 ~ 26.
3.3.2 Wire
insertion/removal
When inserting/removing wires to/from the terminal block, push the driver as shown below and
insert or remove the wire.
3.3.3 Sensor connections & settings
3.3.3.1 Specification
The sensor specifications are as follows.
No. of inputs
16 transistor input
Input types
N.C, N.O support
Specification
Support Sensor
Dry contact sensor
Summary of Contents for SVR-3200
Page 1: ...Install Manual 0 ...
Page 51: ...Install Manual 50 Dimensions SVR 3200 SVR 1680 SVR 1660 SVR 1645 ...
Page 52: ...Install Manual 51 SVR 960 ...
Page 53: ...Install Manual 52 SVR 945 ...
Page 54: ...Install Manual 53 ...