Adjustment
5-8
SAMSUNG
5-7 PUNT ADJ
■
Adjustment objective:
After replacing the MAIN PCB and BARREL, you must decide the AF search range so that the optimal
focus can be identified by the body tube.
■
Necessary equipment:
Infinity Callimator
<Adjustment method>
1. Save the adjustment file to the microSD
TM
card and install it on the camera.
2. Refer to the following adjustment environment specification to adjust the focus.
1) Used specification of Infinity Callimator
- Set the illuminance specification of the Callimator to 6 LV.
- Maintain distance of less than 1cm between the end of the camera body tube to the lens surface of the Infinity Callimator.
- The camera must be fixed while the adjustment is made.
2) Used specification for infinite object
- The camera must be fixed with a tripod and leveled condition must be maintained.
- Set up the camera toward a building or object in infinite distance (more than 500m). (Do not use the chart)
- Set a cathedral, partment or object with high contrast in day environment/AF area display.
Fig. 5-5
Infinity Callimator
Camera
Tripod