background image

15

User’s Guide

14

%

CAMERA SET
If you want to make a set-up related to 
the Samsung  Dome Camera, move
CURSOR(

) to CAMERA SET in the

main menu, and press the ENTER button.
After this, you can set up while watching
the OSD menu screen in a monitor in
which camera visuals can be displayed.

^

MATRIX SET
If you want to make a set-up related to the
matrix switcher, move CURSOR(

) to

MATRIX SET in the main menu, and
press the ENTER button. After this, you
can set up while watching the OSD menu
screen in a monitor in which camera
visuals can be displayed.

&

PRESET SET
In order to set up the preset of the 
receiver unit (or Samsung  Dome Camera),
move CURSOR(

) to PRESET SET in the

CAMERA SET MENU, and press the
ENTER button. First, move CURSOR(

)

to preset no., press the ENTER button, put
in the number, and press the ENTER
button. Next, move CURSOR(

) to

position set, control pan/tilt and the lens,
and press the ENTER button. If you want to
cancel the concerned preset no., move
CURSOR(

) to delete, and press the

ENTER button. 
If you want to go back to the main menu,
press the MENU button.

$

-1 PASSWORD SETUP

– For password input, move CURSOR(

)

to PASSWORD SET, press ENTER, 
and put in the 4-digit number.

– For the selection regarding whether to

use a password or not, move
CURSOR(

) to disable (or enable),

and press ENTER. Each time you
press a button, enable and disable
change. When you come out of the 
set-up mode press the MENU button.

$

-2 BAUD RATE SETUP

Move CURSOR(

) to the Baud rate 

you want, and press the ENTER button.

38400, 19200, 9600, 4800, 2400, 1200

$

-3 PROTOCOL SETUP

Place the CURSOR (

) over a desired

protocol and press the ENTER button.

∗ 

SAMSUNG, PELCO-D, PELCO-P, VICON
PANASONIC, KALATEL, DIAMOND, AD,
PHILIPS, ERNA, VCL TP, TECHWIN,
HONEYWELL

$

-4 When you set up the controller address,

move CURSOR(

) to ADDRESS NO.,

press and ENTER button, put in the
number, and press the ENTER button.

If only one unit is used, set to “0”.

You can not control the currently operating
device in other place, and a message of
"BUSY" appears if you try to do so.

PASSWORD SET
ENABLE

38400
19200

9600
4800

SAMSUNG
PELCO-D
PELCO-P
VICON

M ON = [ 0 0 ]

CAM=[ 0 0 0 ]

CAMERA

MENU

PRESET

S ET

D AT A BACK

UP

MON = [00]

CAM = [000]

CAMERA SETUP  

MATRIX SET  

MENU KEY: < EXIT >

M ON = [ 0 0 ]

CAM=[ 0 0 0 ]

PRESET NO [ 0 0 0 ]
POS I T I ON SET
DE L E TE

SSC-1000 (gb)  2009.1.8  1:38 PM  Page 14

Summary of Contents for SSC-1000

Page 1: ...SYSTEM CONTROLLER SSC 1000 User s Guide SSC 1000 gb 2009 1 8 1 38 PM Page 24 ...

Page 2: ...on point within an equilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the appliance Warning To Prevent Fire or Shock Hazard Do Not Expose This Equipment To Rain or Moisture CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER OR BACK NO USER SERVICEABLE PARTS INSIDE REFER SERVIC...

Page 3: ...face This video product should never be places near or over a radiator or heat register This video product should not be placed in a built in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer s instructions have been adhered to IMPORTANT SAFEGUARDS 1 Read instructions All the safety and operating instructions should be read before the appliance is op...

Page 4: ...o service this video product yourself as opening or removing covers may expose you to dangerous voltage or other hazards Refer all servicing to qualified service personnel 16 Damage requiring service Unplug this video product from the wall outlet and refer servicing to qualified service personnel under the following conditions a When the power supply cord or plug is damaged b If liquid has been sp...

Page 5: ...aximum of 128 units of Multiplex or a maximum of 32 receiver units 4 Connection and use of multiple System Controllers are possible The system can be controlled from each different place and a maximum of 8 units can be simultaneously connected and used However if multiple units are operated simultaneously mal functioning caused by communication error may take place 5 Convenience of manipulation An...

Page 6: ...ned on and when you come out of the selection mode LED gets turned off 9 PATTERN This is used when executing the PATTERN mode set up in the Samsung Dome Camera When you select the PATTERN mode LED gets turned on and when you come out LED gets turned off 10 SCAN This is used when consecutively scanning the PRESET set up in the Samsung Dome Camera When the scan mode is selected LED gets turned on an...

Page 7: ...N This is used when repeatedly moving the two spots of the Pan Tilt connected to the Samsung Dome Camera or the receiver unit When you select the AUTO PAN Mode LED gets turned on and when you come out LED gets turned off 12 RESET RESET ERASE This is used when canceling the ALARM Mode in a condition in which an ALARM has occurred It is equivalent to RESET ERASE button in the Multiplex control mode ...

Page 8: ...ntroller Moves of items are done by the and buttons and for selection you can press the ENTER button When you come out of the controller menu press the MENU button 3 Installation and Connection 1 Connect the RS 485 Cable Connect the Samsung Dome Camera Multiplex or the RS 485 cable of the receiver unit to the out terminal and connect the RS 485 cable of a different controller to the RX in terminal...

Page 9: ...main menu press the MENU button 1 PASSWORD SETUP For password input move CURSOR to PASSWORD SET press ENTER and put in the 4 digit number For the selection regarding whether to use a password or not move CURSOR to disable or enable and press ENTER Each time you press a button enable and disable change When you come out of the set up mode press the MENU button 2 BAUD RATE SETUP Move CURSOR to the B...

Page 10: ...ttern action press the PATTERN button once again PRESET action This is a function for selecting and watching the preset position set up in the camera If you want to select the PRESET Position you want press the PRESET button put in the appropriate number in the position you want and press the ENTER button At this time the LED of the PRESET button gets turned on Pattern gets indicated in the LCD On...

Page 11: ... button If you want to convert the SEQUENCE RUN Mode to the manual select mode press CAM NO ENTER 3 Manipulating the RECEIVER UNIT For receiver unit manipulation as only those applying to the cam no indicated in the LCD are possible first select the camera you wan to manipulate For camera selection when you press CAM NO ENTER the concerned camera number gets indicated in the LCD The camera number ...

Page 12: ... converted to the next Salvo No or the previous Salvo No All Salvo No modes get consecutively converted and SALVO NO RUN gets indicated in the LCD In this state if you press Hold it gets fixed to the previous Salvo No mode For conversion to the manual select mode press CAM NO ENTER 5 Manipulating the MULTIPLEX Into the multiplex control mode You get into the multiplex control mode by pressing MUX ...

Page 13: ...u can go into the set up menu The contents and the circuits in this explanation can be changed due to such reasons as the functional improvement of the production 6 Specifications ITEM SPECIFICATION Communication Interface Type RS 485 Port Connector Type Modular Type x2 D SUB x1 Baud Rate 1200 2400 4800 9600 19200 38400 BPS SAMSUNG PELCO D PELCO P VICON PROTOCOL PANASONIC KALATEL DIAMOND AD PHILIP...

Reviews: