background image

24_

 

troubleshooting

troubleshooting

TROUBLESHOOTING

If the product does not work properly, please check the followings before contacting us. If the trouble persists, please 
contact the SAMSUNG Customer Service near you.

Problem Action

Can I specify RF only or RF+P/W 
mode differently according to the 
card?

1)  It is not available.

2)   The mode is defi ned for each reader device, not the card.

Thus, you can not specify the mode for each card differently.

Ever since I mass-transferred data 
using the PC application, some 
cards are not allowed for access. 

1)   You might have not saved card information to the PC, but just to the device 

when registering card using the PC application.

2)   Check if there is a registered, but disallowed card in the PC.

3)   For an unregistered card, try to enter it again and save to the PC before 

transferring to the device.

4)   The Mass Transfer/Group Transfer function of the PC application will delete 

all card data in the device before transferring the PC data to the device. As 
such, if you usually register one card on a daily basis, you may not save it 
to the PC but transfer to the device, which causes unsaved card numbers 
not to be registered with the device in the operation of a mass-transfer.

5)   If this is not the case, the problem may be caused by the defective of an 

internal circuit.
Contact the nearest customer service for technical assistance.

The RF card works normally, but 
the key input (for the card number) 
using the keypad does not work 
properly.

Use the provided software program to check the use of the keypad while the 
reader is operating in a certain mode.
Enable the use of the keypad before downloading data to the device.

The reader reads a card normally 
but no reaction is made by the 
device or an irrelevant card number 
is displayed.

1)   Check the power source of the reader. (Check if the LED indicator of the 

reader is blinking when it has read a card.)

2)   Check if the reader works properly. (Disconnect the reader from the system 

and use a measuring device such as an oscilloscope to measure the output 
port of the reader.)

3)   Check if the reader is properly connected to the system (device).

       -  Check if the Wiegand communication lines between the reader and the 

system are properly established. (D0, D1)   

       -  The Wiegand communication line should be connected to GND. (A 

different power source may be fi ne but the earth-grounding point should 
be connected to GND of the device.)

4)   If you fi nd the output signal from the device but with severe noise when 

using a measuring device to measure the Wiegand communication line, 
please check the followings:

       -  Connect the shield wire and the spare wire of the cable to GND.

       - Use the repeater.

5)  

If the problem persists after performing all the checkpoints above, contact the customer 
service for technical help.

Summary of Contents for SSA-P400

Page 1: ...ol Panel user manual SSA P400 SSA P400T SSA P401 SSA P401T imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsung...

Page 2: ...injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers lled with water on top of the controller Doing so may cause personal injury due to re electric shock or fal...

Page 3: ...vided plug does not t into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacle...

Page 4: ...ECTION 13 13 Connecting the termination resistor and diode 14 Earth grounding the communication cables 15 Power Reader and I O Connection 18 Communication Line Connection INITIALIZATION 22 22 System I...

Page 5: ...ow access by reading data from the card reader and controls the open close of the door relay and enables you to change other output settings Upon receipt of an incoming external input signal sensor or...

Page 6: ...o set the output time for these output ports Holiday Setup You can specify a holiday legal holiday or bi weekly holiday excluding Sunday You can specify up to 100 holidays for a single holiday code Ac...

Page 7: ...English7 PRODUCT INTRODUCTION WHAT S INCLUDED Check if the following items are included in the product package x Gn Main Unit Quick Guide CD Manual Diode x12 UF4004 1N4001 4007...

Page 8: ...stem Initialization Switch Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both switches will stop the beep and restarts the system af...

Page 9: ...onnection Port Optional item 16 TCP IP Module Connection Port The TCP IP module is optional so it is not provided by default Communication can be established using the built in TCP IP module Communica...

Page 10: ...red indicator turns on in the normal power supply condition 3 Main Board Connection Port Connector used to connect to the main board 4 Output Relay 5 Port Output port 5 5 Output Relay 6 Port Output po...

Page 11: ...13 14 INPUT 14 Input port 14 15 INPUT 15 Input port 15 16 Output Relay 9 Port Output port 9 FORM C 17 Output Relay 10 Port Output port 10 FORM C 18 Output Relay 11 Port Output port 11 FORM C 19 Outpu...

Page 12: ...Door Lock Alarm Device Lock Alarm Device Belden 9409 18AWG 2 Conductor Unshielded 5 RS 232 Cable Converter Host P C Belden 9829 24 AWG 2 twisted pair Shielded 6 RS 485 Cable Device Device Device Conv...

Page 13: ...you connected an inductor door lock or alarm device to the output relay there should occur a voltage surge while the inductor was between turning on and turning off If you do not connect a bypass dio...

Page 14: ...s current ow will introduce some noise and interference to communications It is recommended to connect ONLY one end of the shield wire of the communication cable to the grounding system If you can loc...

Page 15: ...a 1 line of the reader to its port data 1 D1 Door Number External Reader Internal Reader Exit Button Two Door Control 1 Reader 1 Reader 2 None 2 Reader 3 Reader 4 None Three Door Control 1 Reader 1 Re...

Page 16: ...e input port Door 1 Input 2 Door 2 Input 4 of the door sensor Connect the other line NC of the door sensor to GND Door Number Exit Button Door Open Sensor Note Two Door Control 1 Input 1 Input 2 2 Inp...

Page 17: ...Alarm Device Connection Door 1 Alarm Relay 2 Door 2 Alarm Relay 4 Connect the COM line of the alarm device relay to DC 12V Connect the plus line of the alarm device to the NO line of the alarm device...

Page 18: ...he 9 pin connector for RS 232 communications as follows Connect RS 232 TX to pin 2 of the 9 pin connector Connect RS 232 RX to pin 3 of the 9 pin connector Connect RS 232 GND to pin 5 of the 9 pin con...

Page 19: ...he RX port of the converter Connect RS 422 TX to the RX port of the converter Connect RS 422 RX to the TX port of the converter Connect RS 422 RX to the TX port of the converter Connect the 9 pin conn...

Page 20: ...to RX of other one Set a unique board ID for each product Follow the guidelines below to make connection between the terminal device and the RS 422 9 pin connector of the RS 422 RS 232 converter Conne...

Page 21: ...CP IP Connection Connect the LAN cable to the TCP IP RJ 45 jack as shown applicable only to SSA P400T SSA P401T Connect the RJ45 jack of the unit to the RJ45 plug the LAN cable of the network system S...

Page 22: ...ialize switch on the upper right corner and press both switches simultaneously Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both sw...

Page 23: ...itches are defaulted to OFF Each switch has a unique value and the board ID is the sum of the values of the switches You can specify between 0 and 255 for the board ID Refer to the example below for t...

Page 24: ...ve of an internal circuit Contact the nearest customer service for technical assistance The RF card works normally but the key input for the card number using the keypad does not work properly Use the...

Page 25: ...able of the converter RX Port TX RX TX GND GND TX RX TX RX Rs 422 Multi Unit Communication SSA P400 SSA P400 RS 232 RS 422 PC RX RX TX Connected to the RS 232 cable of the converter RX RX TX TX TX RX...

Page 26: ...t Burst for PIN Door Open Time 00 99 Sec Default 3Sec Communication RS232 RS422 RS485 RS232 RS422 RS485 TCP IP RS232 RS422 RS485 RS232 RS422 RS485 TCP IP Baud Rate bps 9 600bps Input Port 15ea Output...

Page 27: ...aste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that...

Reviews: