background image

2_

 

safety information

safety information

CAUTION

RISK OF ELECTRIC SHOCK.

DO NOT OPEN

CAUTION

:  TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK) NO USER SERVICEABLE 

PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

This symbol indicates that dangerous voltage consisting a risk of electric shock is 
present within this unit.

This exclamation point symbol is intended to alert the user to the presence of 
important operating and maintenance (servicing) instructions in the literature 
accompanying the appliance.

WARNING

To reduce the risk of fi re or electric shock, do not expose this appliance to rain or moisture.

WARNING

Be sure to use only the standard adapter that is specifi ed in the specifi cation sheet.
Using any other adapter could cause fi re, electrical shock, or damage to the product.

Incorrectly connecting the power supply or replacing battery may cause explosion, fi re, electric shock, or damage to 
the product.

Do not connect multiple controllers to a single adapter. Exceeding the capacity may cause abnormal heat generation or fi re.

Securely plug the power cord into the power receptacle. Insecure connection may cause fi re.

When installing the controller, fasten it securely and fi rmly. The fall of controller may cause personal injury.

Do not place conductive objects (e.g. screwdrivers, coins, metal parts, etc.) or containers fi lled with water on top of the 
controller. Doing so may cause personal injury due to fi re, electric shock, or falling objects.

Do not install the unit in humid, dusty, or sooty locations. Doing so may cause fi re or electric shock.

If any unusual smells or smoke come from the unit, stop using the product. In such case, immediately disconnect the 
power source and contact the service center. Continued use in such a condition may cause fi re or electric shock.

If this product fails to operate normally, contact the nearest service center. Never disassemble or modify this product in 
any way. (SAMSUNG is not liable for problems caused by unauthorized modifi cations or attempted repair.)

. When cleaning, do not spray water directly onto parts of the product. Doing so may cause fi re or electric shock.

CAUTION

Do not drop objects on the product or apply strong blows to it. Keep away from a location subject to excessive 
vibration or magnetic interference.

Do not install in a location subject to high temperature (over 50°C), low temperature (below 0°C), or high humidity. 
Doing so may cause fi re or electric shock.

If you want to relocate the already installed product, be sure to turn off the power and then move or reinstall it.

Remove the power plug from the outlet when there is a lighting storm. Neglecting to do so may cause fi re or damage 
to the product.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

1.

2.

3.

4.

Summary of Contents for SSA-P102

Page 1: ...cess Control Panel user manual SSA P102 SSA P102T imagine the possibilities Thank you for purchasing this Samsung product To receive more complete service please visit our website www samsungsecurity com ...

Page 2: ...l injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers filled with water on top of the controller Doing so may cause personal injury due to fire electric shock or falling objects Do not install the unit in humid dusty or sooty locations Doing so may cause fire or electric shock If any unusual smells or smoke come from the unit stop using the product In such case...

Page 3: ...provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with cart stand tripod bracket or table specified by the manufacturer or so...

Page 4: ... termination resistor and diode 11 Earth grounding the communication cables 12 Power Reader and I O Connection 15 Communication Line Connection INITIALIZATION 19 19 System Initialization 19 Reader Input Bit Setup 20 Board ID Setting 20 Communication Speed Setup TROUBLESHOOTING 21 21 Troubleshooting PRODUCT SPECIFICATIONS 23 23 Product Specifications ...

Page 5: ...ith two card readers you can use this product to control the access on a single door This controller determines to allow access by reading data from the card reader and controls the open close of the door relay and enables you to change other output settings Upon receipt of an incoming external input signal sensor or Exit button it launches an output device such as the relay This controller has an...

Page 6: ...r senses any forced opening of the door In case of a forced opened door the product does not check the time out Holiday Setup You can specify a holiday legal holiday or bi weekly holiday excluding Sunday You can specify up to 32 holidays for a single holiday code Access can be permitted only for an allowable time range according to your time schedule setting A holiday code can be assigned to the t...

Page 7: ...Switch 4 System Initialize Switch Pressing both of the switches at the same time for about 2 seconds will sound initialization ready beep Releasing both switches will stop the beep and restarts the system after the initialization 5 RJ 45 Connect the LAN cable for TCP IP communications 6 LED Indicates the state of the LAN communications 7 RL 1 RL 2 Ports where the buzzer control line or the LED con...

Page 8: ... 1 Reader port 17 BUZZER It will sound beeps on system initialization to the configured output depending on the buzzer control settings 18 LCD Connection Port Optional item 19 Keypad Connection Port Optional item 20 Power Connection Port SSA P102 uses DC 12V for its power source 21 TTL Output 1 TTL output port 22 TTL Output 2 TTL output port 23 Relay Output 1 Relay output port 24 Relay Output 2 Rel...

Page 9: ...or Lock Alarm Device Lock Alarm This product Belden 9409 18AWG 2 Conductor Unshielded 5 RS 232 Cable Converter Host P C Belden 9829 24 AWG 2 twisted pair Shielded 6 RS 485 Cable SSA P102 SSA P102 SSA P102 Converter Belden 9829 24 AWG 2 twisted pair Shielded RS 422 Cable SSA P102 SSA P102 SSA P102 Converter Belden 9830 24 AWG 3 twisted pair Shielded The cables should be thick enough to allow the ma...

Page 10: ...u connected an inductor door lock or alarm device to the output relay there should occur a voltage surge while the inductor was between turning on and turning off If you do not connect a bypass diode to the relay the voltage surge will cause damage to the electric circuit of the controller To reduce this surge it is recommended to connect a bypass diode to the relay DC DC Lock Alarm SSA P102 1N400...

Page 11: ... and interference to communications It is recommended to connect ONLY one end of the shield wire of the communication cable to the grounding system If you can locate an earth grounding point nearby connect one end of the shield wire to that point If you could hardly locate an earth grounding point nearby connect one end of the shield wire to the chassis ground point If you could locate neither of ...

Page 12: ...ower sources for the reader than supplied from the specified port however all power sources should be connected to the common GND port Failure of the GND grounding will cause a transfer error of Wigand data to the controller due to a voltage difference Connect Wiegand Data Output 0 of the proximity reader to the D0 port and connect Wiegand Data Output 1 to the D1 port of P102 T X Y Z _ lzj lu W i ...

Page 13: ...iary Device Connection AUX 3 AUX 4 AUX 5 Connect one line of the auxiliary input device to any one of IN3 IN 4 and IN 5 Connect the other end of the auxiliary input device to GND 2 2kΩ Resistor Connection for Short Circuit Check To enable the short circuit check function you must have connected a 2 2KΩ resistor between the input line ex orange and the ground line GND First specify if you check eac...

Page 14: ...o the Normal Close NC line of the Door Lock relay Connect the minus line of the Door Lock to the grouding line GND If the Door Lock type is POWER FAIL SECURE Connect the COM common line of the Door Lock relay to DC 12V red Connect the plus line of the Door Lock to the Normal Open NO line of the Door Lock relay Connect the minus line of the Door Lock to the grounding line GND Alarm Device Connectio...

Page 15: ...ector for RS 232 communications as follows Connect RS 232 TX to pin 2 of the 9 pin connector Connect RS 232 TX to pin 3 of the 9 pin connector Connect RS 232 GND to pin 5 of the 9 pin connector Connect the serial communication connector to the serial COM port of the computer Install and launch the application SAMS Check the location of the communication port 1 2 3 4 5 2 3 5 9 Pin Female Connector ...

Page 16: ... RS 422 TX to the RX port of the converter Connect RS 422 TX to the RX port of the converter Connect RS 422 RX to the TX port of the converter Connect RS 422 RX to the TX port of the converter Connect the 9 pin connector of the RS 422 RS 232 converter to the serial COM port of the computer Install and launch the application SAMS Check the location of the communication port 1 2 3 4 5 6 RX RX TX TX ...

Page 17: ...her one Set a unique board ID for each product Follow the guidelines below to make connection between the terminal device and the RS 422 9 pin connector of the RS 422 RS 232 converter Connect RS 422 TX to the RX port of the converter Connect RS 422 TX to the RX port of the converter Connect RS 422 RX to the TX port of the converter Connect RS 422 RX to the TX port of the converter Connect the 9 pi...

Page 18: ...ection SSA P102T is required to establish TCP IP communications 2 Cabling Connect the LAN cable to the TCP IP RJ 45 jack as shown Connect the RJ45 jack of the unit to the RJ45 plug the LAN cable of the network system Set a unique communication address COMM ADDR for each unit Install and launch the application SAMS J 1 2 3 PC TCP IP TCP IP HUB ...

Page 19: ... product until the initialization process is completed READER INPUT BIT SETUP The initial value of the switch is 0 and all of the two switches are defaulted to OFF The default setting is 26BIT Use the switch to set the value For 26 Bit Wiegand KS022H ON 1 2 8J Not used KS022H ON 1 2 8J For 34 Bit Wiegand KS022H ON 1 2 8J KS022H ON 1 2 8J You can not configure any setting for a device that contains ...

Page 20: ... becomes the address of the device so the controllers in the same loop should be identified with each other COMMUNICATION SPEED SETUP The initial value of the switch is 0 and all of the 8 switches are defaulted to OFF Each changing the switch makes a beep and the communication speed changes immediately upon the switch setting Use the switch to set the value 9600 bps Default Setting 4800 bps 19200 b...

Page 21: ...ed by the defective of an internal circuit Contact the nearest customer service for technical assistance A RF card is normally recognized by my presenting it to the reader but is not recognized using the keypad If the keypad operation does not work at all as a means of authenticating the card use the PC application to check if the reader is set to use the keypad values The reader reads a card norm...

Page 22: ...ess and match it with that of the PC application Specify a unique board ID COMM address for each of the multiple devices Check the baud rate if it matches with the PC application Check if the communication port of the PC matches that of the PC application Check the communication settings of the PC application Parity Bit NONE Data Bit 8bit Stop Bit 1bit 2 Check the connection staus of RS 232 and RS...

Page 23: ...RS232 RS422 RS485 RS232 RS422 RS485 TCP IP Baud Rate bps 4800 9 600 19 200 38 400 57 600 default 115 200 selectable Input Port 5ea Exit Button Door Sensor Aux 1 2 3 Output Port 2ea 2 FORM C Relay Output COM NO NC DC12V 18V Rating Max 2A 2ea TTL Output DC5V Rating Max 20mA LED Indicator 16 LED Indicators Red Blue and Yellow Beeper Piezo Buzzer Operating Temperature 0 C to 50 C Operating Humidity 10...

Page 24: ...Waste Electrical Electronic Equipment Applicable in the European Union and other European countries with separate collection systems This marking on the product accessories or literature indicates that the product and its electronic accessories e g charger headset USB cable should not be disposed of with other household waste at the end of their working life To prevent possible harm to the environ...

Reviews: