![Samsung SPC-300 User Manual Download Page 18](http://html.mh-extra.com/html/samsung/spc-300/spc-300_user-manual_353732018.webp)
18
– COAXIAL REMOTE CONTROLLER
Connection & Control
SWITCH SETTING TABLE
Use a combination of pin 1,2,3 of the Protocol setting switch to select a protocol.
TERMINATION
1
ON
2
PROTOCOL
1
ON
2 3 4 5 6 7 8
1
ON
2 3
Protocol Setting Switch
(0 :
r
, 1 :
q
)
Protocol
HALF/
FULL
Software
Type
(A, B, C, D)
PIN 1
PIN 2
PIN 3
0
0
0
SAMSUNG-E
HALF
ALL
1
0
0
SAMSUNG-E
FULL
ALL
0
1
0
SAMSUNG-T
SIMPLEX
A
1
1
0
SAMSUNG-T
FULL
A
0
0
1
PELCO-D
SIMPLEX
A
1
0
1
PELCO-D
FULL
A
0
1
1
PELCO-P
SIMPLEX
A
0
0
1
PANASONIC
HALF
B
1
0
1
PANASONIC
FULL
B
0
0
1
HONEYWELL
SIMPLEX
C
1
0
1
HONEYWELL
FULL
C
0
0
1
VICON
HALF
D
1
0
1
VICON
FULL
D
0
1
1
AD
SIMPLEX
D
1
1
1
AD
FULL
D
Use pin 4, 7 and 8 of the Protocol setting switch to set the coaxial output.
PROTOCOL
1
ON
2 3 4 5 6 7 8
4
PIN 4
Output Selection
ON
COAXITRON
OFF
A1
COAXIAL
PROTOCOL
1
ON
2 3 4 5 6 7 8
7
PIN 7
Output Selection
ON
COAXIAL OUT
OFF
RS-485 OUT
PROTOCOL
1
ON
2 3 4 5 6 7 8
8
PIN 8
RS-232 input
ON
RS-232 input
OFF
RS-232 No use
❖
❖
Setting of the PIN 7 overrides that of PIN 4.
NOTE