background image

10

 – COAXIAL REMOTE CONTROLLER

Introduction

Rear Panel

PART NAMES AND FUNCTIONS

 AA BATTERY

You can use 4 AA-sized batteries for the power.

-  The average operation time is 20 hours based on the alkaline battery.

(If the battery is discharged, it can cause a distortion of the video signal, or 
electric interference.)

Remove the battery if you do not use the controller for a longer period. Otherwise, it 
may cause damage to the controller from a leak of the battery solution.

Take caution not to change the specified polarity.

Do not use a new battery with an old one.

For storing used batteries, keep out of reach of children. Wasted batteries are to be 
collected separately.

ƒ

ƒ
ƒ
ƒ

NOTE

Summary of Contents for SPC-300

Page 1: ...COAXIAL REMOTE CONTROLLER User Manual SPC 300 ...

Page 2: ...e integrity and correctness of the contents in this document but no formal guarantee shall be provided Use of this document and the subsequent results shall be entirely on the user s own responsibility Samsung Techwin reserves the right to change the contents of this document without prior notice Warranty If the product does not operate properly in normal conditions please let us know Samsung Tech...

Page 3: ...a single adapter Exceeding the capacity may cause abnormal heat generation or fire Securely plug the power cord into the power receptacle Insecure connection may cause fire When installing the controller fasten it securely and firmly The fall of controller may cause personal injury Do not place conductive objects e g screwdrivers coins metal parts etc or containers filled with water on top of the cont...

Page 4: ...ther household waste at the end of their working life Where marked the chemical symbols Hg Cd or Pb indicate that the battery contains mercury cadmium or lead above the reference levels in EC Directive 2006 66 If batteries are not properly disposed of these substances can cause harm to human health or the environment To protect natural resources and to promote material reuse please separate batter...

Page 5: ... an electrician for replacement of the obsolete outlet Protect the power cord from being walked on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus Only use attachments accessories specified by the manufacturer Use only with cart stand tripod bracket or table specified by the manufacturer or sold with the apparatus Unplug this apparatus when a...

Page 6: ...Control the camera coaxial communications 12 To control the camera using RS 485 device via coaxial communications 13 To control the camera using RS 232 device via coaxial communications 14 To control the camera using RS 485 signal output 15 To control the camera using RS 485 signal output via RS 232 communications 16 Switch Setting Table 17 Specifications Specifications 20 Dimensions 21 IN T a ...

Page 7: ...ation Features Long distance remote control Through RS 485 communication remote control is possible up to 1 2 kilometers Easy Control Easy and simple 5 way keys for controlling the camera List of controllable models Capable of controlling A1 series camera products You can control cameras supporting COAXITRON What s Included Controller User Guide COAXIAL REMOTE CONTROLLER UserManual SPC 300 ...

Page 8: ...his switch for amplifying the control signal RS 485 TERMINATION PROTOCOL Setting Switch You can select to set the RS 485 termination left 2 pin piano switch To set the RS 485 termination left 2 pin piano switch turn the switch ON TERMINATION 1 ON 2 PROTOCOL 1 ON 2 3 4 5 6 7 8 1 ON 2 3 4 5 6 7 8 PROTOCOL Front Panel N POWER POWER ADDRESS X 100 X 10 TERMINATION PROTOCOL 1 ON 2 3 4 5 6 7 8 X 1 OFF ON...

Page 9: ...OAXIAL BNC communication or RS 485 output Use pin 8 of the Protocol setting switch to select RS 232 input Address Switch For RS 232 RS 485 communications you can use this switch to set the address ADDRESS X 100 X 10 X 1 5 0 4 9 3 8 2 7 1 6 5 0 4 9 3 8 2 7 1 6 5 0 4 9 3 8 2 7 1 6 Set the address by using three switches shown above From the left the number is hundreds tens and ones place respectivel...

Page 10: ...ged it can cause a distortion of the video signal or electric interference Remove the battery if you do not use the controller for a longer period Otherwise it may cause damage to the controller from a leak of the battery solution Take caution not to change the specified polarity Do not use a new battery with an old one For storing used batteries keep out of reach of children Wasted batteries are ...

Page 11: ...ly using RS 485 communication VIDEO IN OUT Connector BNC VIDEO IN receives coaxial communication from cameras and VIDEO OUT outputs the video signal DC12V Power Connector 2 PIN Used for connecting DC12V power source OUT IN TX RX ADDRESS X 100 X 10 X 1 POWER OFF ON CABLE COMPENSATION S L REMOTE CONTROLLER SCP 300 POWER STATUS TERMINATION PROTOCOL 1 ON 2 3 4 5 6 7 8 1 ON 2 RS 232C VIDEO DC 12V RS 48...

Page 12: ...ctric interference or wireless devices such as radio or TV set Keep clean the installation place during and after the installation An abnormal smells from the product is a sign of abnormal condition which may cause fire or electric shock In this case disconnect the product from the main power immediately and contact the retailer for technical help from authorized servicing Keep the product away fro...

Page 13: ... output by using the protocol switch pin 7 The pin 7 coaxial RS 485 has the output priority To select from COAXIAL or COAXITRON use the pin 4 You can use the menu as following Press and hold ENTER Moves to the main menu screen Press ENTER briefly Used to confirm the current settings Four Direction Keys Used to move the cursor up down or left right 1 2 3 4 SCX RD100 No address setting is required for...

Page 14: ...tocol setting switch to select a protocol Refer to the switch configuration table See page 18 Using RS 485 device you can control the camera menu 1 2 3 4 5 6 Each mentioned protocol may require updating the firmware from the website By factory default protocols of SAMSUNG E SAMSUNG T and PELCO D P are supported To support additional protocol access the website to update the program RS 232 and RS 48...

Page 15: ...munication will not be established Connect VIDEO OUT of the main unit to a monitor s video input terminal Connect the RS 232 device s cable to the RS 232 port of the main unit Using RS 232 device you can control the camera menu The RS 232 device is the same as RS 485 regarding the protocol setting but supports only the Samsung protocol For proper coaxial communication AI camera should be set to Sa...

Page 16: ...trol the camera by using the menus You can use the menu as following Press and hold ENTER Moves to the main menu screen To exit the menu screen press and hold the key again Press ENTER briefly Used to confirm the current settings Four Direction Keys Used to move the cursor up down or left right Control of pan tilt zoom using the buttons is not supported 1 2 3 3 RS 232 and RS 485 communications canno...

Page 17: ...d rate and protocol to the same to those of the unit RS 232 device control supports SAMSUNG E protocol only Connect the RS 232 device s cable to the RS 232 port of the main unit Using RS 232 device you can control the camera menu 1 2 3 4 5 6 RS 232 and RS 485 communications cannot be used for simultaneous input For the switch settings see the switch setting table See page 18 Input of video signal ...

Page 18: ...1 PELCO D SIMPLEX A 1 0 1 PELCO D FULL A 0 1 1 PELCO P SIMPLEX A 0 0 1 PANASONIC HALF B 1 0 1 PANASONIC FULL B 0 0 1 HONEYWELL SIMPLEX C 1 0 1 HONEYWELL FULL C 0 0 1 VICON HALF D 1 0 1 VICON FULL D 0 1 1 AD SIMPLEX D 1 1 1 AD FULL D Use pin 4 7 and 8 of the Protocol setting switch to set the coaxial output PROTOCOL 1 ON 2 3 4 5 6 7 8 4 PIN 4 Output Selection ON COAXITRON OFF A1 COAXIAL PROTOCOL 1 ...

Page 19: ... 19 Connection Control t See the following table to set the baud rate TERMINATION 1 ON 2 PROTOCOL 1 ON 2 3 4 5 6 7 8 5 6 BAUD RATE PIN 5 PIN 6 38400 BPS OFF OFF 19200 BPS ON OFF 9600 BPS OFF ON 4800 BPS ON ON ...

Page 20: ... RS 485 Connector Type 4P Terminal Type Port 1 Port BAUD RATE 4800 9600 19200 38400 bps USB PORT USB2 0 S W PROGRAM UPLOAD VIDEO IN OUT Composite Video 1 0Vp p 75ohm Cable Compensation out Select S L Multi protocol Supports 4 programs A SAMSUNG E SAMSUNG T PELCO D P B SAMSUNG E PANASONIC C SAMSUNG E HONEYWELL D SAMSUNG E VICON AD Environmental Conditions Operating Temp 10 C 50 C Humidity Less than...

Page 21: ...English 21 Specifications DIMENSIONS Unit mm ...

Page 22: ...Korea 463 400 TEL 82 70 7147 8740 60 FAX 82 31 8018 3745 SAMSUNG TECHWIN EUROPE LTD Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey UNITED KINGDOM KT16 OPS TEL 44 1932 45 5300 FAX 44 1932 45 5325 SAMSUNG TECHWIN AMERICA Inc 1480 Charles Willard St Carson CA 90746 UNITED STATES Tol Free 1 877 213 1222 FAX 1 310 632 2195 www samsungcctvusa com SALES NETWORK ...