2-5) External terminal connecting
method for Camera and
Monitor
1) External terminal connecting method for
CAMERA
PIR Sensor
Camera alarm injack
Sensor
input
Sensor
• An additional PIR sensor or external sensor can
also be connected.
• The additional PIR sensor can be connected as
shown in the above graphic.
• Sensor’s trigger signal is NO (Normal Open).
• Sensor is not supplied. (Sold separately)
2) ALARM terminal connecting method.
<SMT-190DN>
<External Recorder>
a. Connect the A/O (HOT) terminal on the rear panel
to the Alarm IN terminal of the VCR.
b. Connect the A/O (COLD) terminal on the rear
panel to the Ground terminal of the VCR.
c. Connect the A/R terminal on the rear panel to the
Alarm Reset terminal of the VCR.
d. Connect the G (ground) terminal on the rear panel
to the Ground terminal of the VCR.
Total System Configuration
MONITOR
SMT-190DN
MONITOR
SMT-190DN
Local System Configuration
MONITOR
SMT-190DN
Eng-1