Installation Instructions
13
B.
RECIRCULATING
(NON-VENTED DUCTLESS)
B1.
ADAPTING MICROWAVE
BLOWER FOR RECIRCULATION
•
NOTE:
The exhaust adaptor with damper is not
needed for recirculating models. You may want to
save them for possible future use.
3.
Remove screw holds blower mortor and
carefully
pull out the blower unit. The wires will extend far
enough to allow you to adjust the blower unit.
CAUTION:
Do not touch blade of blower for
preventing crack and break. Hold outer case when
the blower pull out or back into.
4.
Roll the blower unit 90° so that fan blade
openings are facing toward the front of the
microwave.
5.
Place the blower unit back into the opening.
CAUTION:
Do not pull or stretch the blower unit
wiring. Make sure the wires are not pinched.
6.
Secure blower unit to microwave with the screw.
B2.
INSTALLING THE CHARCOAL
FILTER
1.
Remove screws on top of grille using a #1
Phillips screwdriver.
2.
Open the door.
3.
Remove the grille.
•
After push left, Pull the grille straight off.
4.
Install the charcoal filter. When properly installed,
the wire mesh of the filter should be visible from
the front.
5.
Reinstall the grille and the screws.
6.
Close the door.
1.
Remove and save screw
that holds blower plate to
microwave.
2.
Lift up the
blower plate.
Back of
Microwave
blower mortor screw
Before Roll
Back of
Microwave
Back of
Microwave
After Roll
Charcoal
Filter
Insert mesh-side up
Summary of Contents for SMH1711S
Page 19: ...Installation Instructions 19 NOTE...
Page 20: ...Code No DE68 03587A 03...