Connection with PC for Use
Connection with RS-232C
You can control the system remotely through the parallel communication of RS-232.
A. Communication Method
●
Data Code: ASCII Code
●
Data Transmission Method : Start-Stop Asynchronized Serial Interface
●
Protocol: 8 bit Data, 1 Stop bit, None Parity
●
Transmission speed: 4800, 9600, 19200, 38400 bps
B. RS-232C terminal (D-SUB 9 Pin) and Pin specifications
Pin No
Pin Specifications
2
TXD (Transmitted Data)
3
RXD (Received Data)
5
SG (Signal Ground)
1, 4, 6~9
NO Connection
2-3
DIGITAL VIDEO RECORDER
3
GB
DIGITAL VIDEO RECORDER
System Connection for Alarm Recording
<Rear Side Connection Terminal of SHR-1010>
<Outside Product>
ALARM IN
GND
ALARM OUT
ALARM RESET IN
GND
1 SHOT REC IN
REC START IN
GND
REC END
TRIGGER OUT
■
Alarm recording is a function for recording the input video when an alarm signal is input
while a device with alarm output is connected to this unit.
■
Connect to the corresponding terminals, as the numbers may be different for external
devices.
■
For external devices, if the alarm input (ALARM INPUT) and alarm cancel (ALARM
CANCEL) are not available, you can leave them unconnected.
GND
TRIGGER IN
ALARM IN
ALARM CANCEL
ALARM OUT
1
1
2
3
1
2
3
4
5
2
3
4
5
6
7
8
9
10
1
2
3
4
5
4
5
7
8
9
10
6
RS-232 Port behind SHR-1010 System
Summary of Contents for SHR-1010
Page 4: ...1 GB I Summary ...
Page 10: ...2 II Connection with Other Devices GB ...
Page 14: ...3 GB III Basic Method to use ...
Page 27: ...4 IV Record GB ...
Page 30: ...5 GB V Retrieval and Playback ...
Page 34: ...6 GB VI Others GB ...
Page 36: ...7 GB Appendices ...