background image

9

11

8

10

7

   

Default settings is automatic detection.

 

 

This settings is to automatically or manually detect the Key tags. 

[21] Button :  Automatic Locking Setting
[22] Button :  Manual Locking Setting

  

or

 

By pressing a PIN code in order after two arbitrary numbers are inputted, 

a user can prevent PIN code  leak.

By default, the multi-leveled security code entry mode is set.

 

[ 7] Button : Multi-leveled Security 

Code Entry Mode

[9] Button : Common Mode

Press the [

] button after pressing the

[7] or [9] button, and the security mode
will be set.

DING DONG 

DENG

DING DONG 

DENG

DING DONG 

DENG

Press the [ 

] button after pressing the

[21] or [22] button, and the Automatic/Manual 
Locking mode will be set.

DING DONG 

DING DONG 

Open the battery cover of 

the inner body and press the 
[Register] button shortly.

[1] Button : Automatic Detection Setting 
[3] Button : Manual Detection Setting  

DING DONG 

DENG

DING DONG 

Press the [ 

] button after pressing the

[1] or [3] button, and the key tag 
Auto/Manual Detection mode will be set.

Open the battery cover of 

the inner body and press the 
[Register] button shortly.

Open the battery cover of 

the inner body and press the 
[Register] button shortly.

Open the battery cover of 

the inner body and press the 
[Register] button shortly.

Double authorization mode requires both PIN code and key tag to open the door, 

enhancing more security.

To set the double authorization mode, one or more key tag need to be registered.

When purchased, the door lock is not set to double authorization mode initially.

2-Step Authentication Mode

DING DONG 

[4]Button :  Double authorization 

mode on

[6]Button :  Double authorization 

mode off

Press the [

] button after pressing the

[4] or [6] button, and the authorization

mode will be set.

DING DONG 
DENG

Automatic

Manual

The Automatic Locking mode allows for automatic locking of the door when 

it is closed.

The door is automatically locked 2 seconds after the door is closed.

If the battery an alarm sound are heard, replace the batteries.  

If the voltage of the door lock continues to be low, the door may not be locked. 

The door does not automatically lock, and the [DOUBLE LOCK] button 

must be pressed from the inside or touch [number pad] to close the door.

Auto/Manual Key Tag Reading Function Setting

Randomizer Mode

Automatic/Manual Locking Setting

Regardless of the automatic/manual locking setting, the door will automatically lock 
7 seconds after the door lock is unlocked if the door is not opened.
Under automatic lock settings, if the door is not locked properly, an alarm will go off 
and the warning LED on the indoor unit will flicker.

Note

Privacy Mode Activation

Privacy Mode Deactivation

Inside :   

Press the [CLOSE] button, then the 

sound for action-unavailable willbe 

heard.

Outside :   

Press the [Number Pad] or touch with 

a Key tag, then the sound for action-

unavailable will be heard.

Privacy Mode Operation

Rapid beeping

While the door is locked, press 
[CLOSE] button on the inner body 

part for 3 seconds.

 

   

When the Privacy Mode is activated, the door cannot be unlocked from the
outside, so please be careful. Be especially careful not 
to allow children to set this mode accidently from the inside.

Warning

Press down the inner body handle to 

deactivate privacy mode.

DING DONG 
DENG

Away Mode Activation/Deactivation

Privacy Mode Activation/Deactivation

At-home privacy mode is to prevent opening of the door from outside while 

someone is inside.

To prevent intrusion when a user goes out, this function triggers an alarm 

sound when someone tries to open the door from the inside.

In Away mode, if someone tries to open the door from the inside, “beep- 

beep-” sound is triggered for 5 minutes.

Away Mode Activation

Away Mode Deactivation

Once the door is locked, the [  ] 
button of the number pad is lighted.  
Press the [

] button within 3 seconds 

to activate the Away mode.

Enter the user PIN code, 

touch a registered key tag

 

and open the door to 

deactivate the Away mode.

 

Warning

 

 Away mode function should only be set up when there is no one inside.

 

Double Authentication Mode Operation

Touching 

[Number Pad]. 

Enter the PIN code  

when the number pad is 

lighted, and press the [

button.

Touch the Key tag on to 

the [Key tag Reader], if the 

authentication is successful, 

the door will open.

Success:
DING DONG 

DENG DONG
Fail:  DING DONG 

DING DONG

Success:

Fail:

DING DONG 

DING DONG

BE BE BE BEEP

The door will unlock when the key tag is tagged against the key tag sensor 
during auto detection mode.

Under manual detection mode, you need to touch the number pad and then
key tag against the key tag sensor.

 

Note

 

 

This function triggers an alarm sound when an attempt is made to 

forcefully open the door from the inside or the outside.

(It is a basic function, and cannot be activate/deactivated by the user.)

If the door is forcefully opened while locked, the open/close door sensor 

detects it and triggers an alarm sound for 5 minutes.

Intrusion Detection Function

This function triggers an alarm sound and deactivates lock operation when 

the door lock is improperly handled from the outside.

If a key tag that are not registered or a wrong PIN code  are used five times, 

an alarm sound is generated and the door lock is deactivated for 3 minutes. 

Prank Prevention Function

Open the battery cover on the inner body and press the [Register] button, or 
open the battery cover and separate the batteries. Authenticate a registered 
key tag or pressing the user PIN code  and press the [

] button. 

Alarm Sound Deactivation

If the room temperature abnormally increases, the temperature sensor 

detects it and an alarm is triggered. (It is a basic function, and cannot be 

activate/deactivated by the user.)

This high temperature alarm function is activated at about 

65 °C ± 5°C.

Depending on the installation environment, the temperature may be different. 

When a high temperature occurs, the temperature sensor detects it. 

The LED of the Warning led on the inner body flashes while an 

alarm sound is generated for 15 seconds. After the alarm sound stops,

the door is automatically opened.

(If the room temperature decreases to below a certain temperature, 

the door lock is normally operated.)

High Temperature Alarm Function

Press the [ 

] button after pressing the

[31] ~ [33] button, and the Volume
will be set.

DING DONG 

Open the battery cover of 

the inner body and press the 
[Register] button shortly.

The sound that is generated when the number buttons are pressed, when 

the door is locked, or when the locked door is unlocked, can be set accord

ing to the user’s preference.  

When purchased, all sounds are set to be generated initially. (1 level)

 

- [31] : The sounds of door opening/closing and key touching are not deactivated 

(except an alarm sound).

- [32]~[33] : All sounds are activated, and the sounds get bigger as the step becomes 

higher.

Volume Setting

  

Depending on battery manufacturer, date of manufacture, and the user environment, 

the duration of use may vary. (In the case of average use, given as 10 times a day, 4 

AA alkaline 1.5V batteries can last for 12 months).

  

Liquid leaks from batteries can damage the product. Check the batteries regularly 

(about every 6 months).

  

Before the batteries are replaced after the battery replacement melody sounds, a 

menu function such as activating the registration/setting mode cannot be used.

Warning

 

 

Battery Replacement

When the battery replacement alarm voice is heard, immediately replace all 

batteries with new ones.

- The unit will stop operating suddenly if the batteries are not replaced.

Melody for low battery notification is triggered

(If the battery replacement alarm melody sounds, the battery replacement 

[        ] LED is lighted on the number pad.)

If the melody of “Blues for Elise” sounds when opening the door with the 
PIN code  or a key tag, it is time to replace the batteries.

Replacing the Batteries

or

 

-  

Place the key tag on the Key tag reader, or enter the PIN code , while 

the 9V battery is connected to the external power port of the outer body.

How to open the door Using Emergency Power

If batteries are not replaced on time, they will be completely discharged and 

the lock will not operate.

Purchase an emergency battery (9V) at the nearest store.

 

As the alkaline batteries offer longer life, they are recommended over the 

manganese batteries or rechargeable ones.

Using the Emergency Battery

or

Item

Specifications

Voltage

Four AA Alkaline 1.5 V batteries (LR6) (DC 6 V)

Emergency 

Power Source

Operation 

Method

 

Weight

1.824kg (including both inner and outer bodies)

Product 

Dimensions

(including the 

handle)

Outer Body

77mm (W) X 228.9mm (H) X 63.2mm

 (D)

Inner Body

77mm (W) X 229mm (H) X 73.6mm 

(D) 

Product Specifications

9V Battery (6LF22) (Separately sold)

Electronic Control Method 

(PIN code entry or key tag reading)

12

[31]Button : Mute 
[32]Button : Low
[33]Button : High

Reviews: