SGH-X300 Flow Chart of Troubleshooting
2-3
2-1-2. Initial
Initial Failure
check the pin
RSTB of U300 is
LOW?
Check U300
No
Yes
Yes
END
Yes
Check the Initial Operation
Yes
Check
R103,R107,R200,C130
No
check the pin CKI
of U300 is 13Mhz?
Check the clock signal
at pin #3 of OSC100
Freq=26Mhz?
No
check
OSC100
1
Check the pin #9 of U300
is HIGH and pin #11,
#13 is 2.9V?
No
Check U200
Yes
2
3
4