SGH-X300 Flow Chart of Troubleshooting
2-16
2-2-3. PCS Rx
CONTINOUS RX ON
RF INPUT : 660CH
AMP : -50dbm
Normal condition
catch the
channel ?
Check ANT,
R101,R102,C104,L102
No
1
Yes
Check U102
pin 12
≥
-65
dbm ?
2
Resolder or change
CN100, L101, L102, C100, C105, C106
No
Yes
Check U102
pin 18
≥
-65
dbm ?
Resolder or change
U102
No
3
Yes
Check U101
pin 19,20
≥
-
65dBm ?
4
No
Resolder or change
F100
Yes
Check U101
pin 13 = 2.9V
No
Resolder or change
U200
5
Yes
Resolder or change
U300