SAMSUNG Proprietary-Contents may change without notice
Flow Chart of Troubleshooting
This Document can not be used without Samsung's authorization
9-43
9-17. PCS Receiver
CONTINUOUS RX on
RF input : 698CH
Cell power : -50dBm
RX ON
RF input : 698CH
Cell Power : -50 dBm
Yes
C104
≥ -65dBm
No
Resolder RFS100
Yes
L108
≥ -70dBm
No
Resolder FEM100
Yes
No
RFT100 pin
11,12,13,14
≥500mV
Resolder RFT100 or Check
pins related to RFT100
Yes
Check RFT100
END