English
_55
●
MAIN MENU
HDD Alarm
You can set alarm settings for HDD defects such as Check Alarm Output Port, Replace Alarm Output Port,
and its duration.
Using the mouse may help make setup easier.
1.
Use the up/down buttons (
▲▼
) in <
Device
> window to
move to <
Storage Device
>, and press [
ENTER
] button.
2.
Select <
HDD Alarm
>.
A window for setting HDD check and replace output ports
and their durations appears.
3.
Use direction buttons (
▲▼_ +
) to move to the desired
ite
m.
•
C
heck Alarm Output Port : If HDD generates check alarm,
the alarm signal will output to the specified alarm output
port.
•
Replace Alarm Output Port : If HDD generates replace alarm, the alarm signal will output to the specified
alarm output port.
•
Duration : Sets the alarm duration for the alarm signal and beep soun
d.
- I
f <
BEEP
> was selected, a beep will soun
d.
M
`
<
Check
> status means that the HDD is operating but it has problems that require technical examination.
(
) appears on the Live screen.
`
<
Replace
> status means that the HDD has defect and requires immediate replacement.
(
) appears on the Live screen.
`
If the installed HDD is not recognized properly, a confirmation popup will appear.
4.
When the HDD Alarm setup is done, press <
OK
>.
Remote Devices
You can set the RS-485 communication for use of PTZ Camer
a w
ith the DVR.
Using the mouse may help make setup easier.
1.
Use the up/down buttons (
▲▼
) in <
Device
> window to
move to <
Remote Device
>, and press [
ENTER
] button.
2.
Use direction buttons (
▲▼_ +
) to move to the desired
item, and press [
ENTER
] button.
3.
Set the values of each communication setup of the remote
device.
•
Baudrate : Baud rate settings of the DVR, PTZ camer
a
s
hould be matched for proper operations.
4.
Make sure to match IDs of the DV
R a
nd Remote Control,
and press <
OK
>.
M
`
For changing the remote control’s ID, refer to “
Changing the Remote Control ID
”. (Page 15)
Storage Device
Format
OK
Cancel
Device
HDD Alarm
Check Alarm Output Port
Duration
OFF
BEEP
Replace Alarm Output Port
Duration
OFF
BEEP
Remote Control
ON
ID
0
Baudrate
Parity
Data
Stop Bit
Transfer type
9600
None
8
1
Half Duplex
Remote Device
OK