82_
functional description
functional description
As shown in the picture above, the Alarm Input must be entered with the Open or
Closed switch signals. Supplying power without entering the signals may damage the
product.
P (Priority) :
Set the priority of Alarm Inputs. If more than one alarm is simultaneously
activated, the alarm with the highest priority activates before the others. Once
the alarm is canceled, the next highest priority alarm activates.
SEQ :
Enables setting up a sequence action for the camera in response to an alarm.
Available sequence actions are Home, Preset, Swing, Group, Tour, Trace and
A.Pan.
For the Auto Pan settings, the fi rst number under the Number menu indicates
the speed while the second is the Tilt angle. (Refer below.)
MD Dwell Time :
When Motion Detection under the Preset Edit menu is selected, MD Dwell Time
performs the Tour or Group function.
While the camera is performing a sequence action, if motion is detected from a
selected preset location, the camera pauses the sequence action operation and
starts monitoring the location instead for a duration that is set under the MD
Dwell Time menu.
If the motion is no longer detectable or the duration expires, the camera aborts
the monitoring operation and then resumes the sequence action.
M
•
•
❋
•
ALM
MOD P
SEQ
NO
IN 1
NO
1
A.PAN
20/20
IN 2
NC
2
A.PAN
20/20
Tilt Angle
Speed
Summary of Contents for SCP-3120
Page 1: ...12X SPEED DOME CAMERA User Manual SCP 3120 3120V 3120VH ...
Page 93: ...English English _ 93 DIMENSIONS dimensions 154mm 150mm R60 DIMENSIONS SCP 3120 Unit mm ...
Page 95: ...English English _ 95 DIMENSIONS SCP 3120VH Ø200 R 6 0 NP 1 5Inch Threaded 19 120 184 203 ...
Page 97: ...English English _ 97 MEMO memo ...
Page 98: ...98_ memo memo ...