| 30
RADVISION | RADVISION Port Security Reference Guide
SCOPIA VC240
Table 1-20
lists ports that need to be opened between SCOPIA VC240 and network devices.
Table 1-20
Ports supported by SCOPIA VC240
Port
Protocol/Use
Functionality
Direction Result of Blocking
on Firewall
Description
22
TCP (SSH)
iVIEW Management
Suite and for remote
software upgrades
from iVIEW
Management Suite
Both
iVIEW Management
Suite does not
communicate with
the unit
SSH Server
23
TCP (Telnet)
iVIEW Management
Suite and
administration
Both
iVIEW Management
Suite does not
communicate with
the unit
69
TFTP
Software uprgade
through the device’s
menus
Both
Software upgrade
through TFTP does
not function.
TFTP Server
80
HTTP (TCP)
Open APIs and remote
software uprades
either via the web
interface or via iVIEW
Management Suite
Both
Web server and
open APIs do not
function.
Web-based
software upgrades
will not function
Web application or open
API-based application
161
UDP (SNMP)
Configuration and
status
In
Cannot configure
or check the status
of the terminal via
SNMP
SCOPIA iVIEW Network
Manager, iVIEW
Management Suite or any
other SNMP manager
station
162
UDP (SNMP)
SNMP trap events
Out
Cannot receive
traps
SCOPIA iVIEW Network
Manager, iVIEW
Management Suite or any
other SNMP manager
station
443
HTTPS (TCP)
Open APIs
In
Web server and
open APIs do not
function
Web application or open
API-based application
3230-3241
(configurable)
TCP (H.245)
H.245 signaling
Both Cannot
connect
H.323 calls
Any H.323 entity.
Configure these ports on
the SCOPIA VC240 by
navigating to Setup >
Network > Port