DVR Mode

DVR MODEL Setup

This menu is for setting the DVR ID and model for operation by a
controller. Sub-controllers cannot be used if the master controller is 
in Setup mode.

At the initial screen, press the FUNCTION button and press the 0 button
to activate the [SETUP SYSTEM] menu.

Press the 2 button to activate the [DVR SETUP] menu.

Press the 1 button to activate the [DVR Model SETUP] menu.

Press a number on the number pad to set the DVR ID.
The DVR model name saved in EEPROM will be displayed on the LCD
monitor when changing DVR ID.

Press the + and - buttons to change the DVR model name

(SVR 430 

SVR 900 

SVR 1620 

SVR 1630).

Press the ENTER button to finish the setup.

When connecting to an SVR-430, the SVR-430 system ID must be set to be the same as the controller DVR ID
(Menu 

Network/Communication 

RS422/485 

SYSTEM ID).

When connecting to an SVR-900/1620, the SVR-900/1620 system ID must be set to be the same as the
controller DVR ID (Menu 

System Setup 

Com Port Setup 

SYSTEM ID).

When connecting to an SVR-1630, the SVR-1630 keyboard control address must be set to be the same as the
controller DVR ID (Menu 

System Setup 

Misc.). Also, for the SVR-1630 COM2 RS422/485 menu (Menu 

System Setup 

Serial Port), Device must be set to SCC-3000 and Interface to RS-485, and for the COM4

RS422/485 menu (Menu 

System Setup 

Serial Port), Device must be set to SPD2500 (if an SPD2500 is

connected) and Interface to RS-485.

When controlling a PTZ camera via an SVR-1630, connect the SVR-1630 and the controller to COM2 RX+/RX-
and connect the SVR-1630 and PTZ camera to COM4 RX+/RX-. Also, at the SVR-1630 channel setup menu, set
the PTZ port of each channel to COM4 and set the PTZ address to be the same as the PTZ camera ID. 

SETUP SYSTEM

1:PTZ

2:DVR

3:CONTROLLER

Press Numeric Key

DVR SETUP

1:DVR MODEL SETUP

Press Numeric Key

+,-:Model Change

DVR MODEL SETUP

DVR ID:

0

[

0 ]

MODEL: NONE

+,-:Model Change

DVR MODEL SETUP

DVR ID:

1

[

1 ]

MODEL: SVR430

When entering '1'

Summary of Contents for SCC-3000

Page 1: ...Thank you for buying a Samsung SYSTEM CONTROLLER This manual will guide you through using the SYSTEM CONTROLLER Please read this manual carefully before using the SYSTEM CONTROLLER ...

Page 2: ...NG Setup 17 3 2 SWING Operation 17 4 GROUP 18 4 1 GROUP Setup 18 4 2 GROUP Operation 18 5 TOUR 19 5 1 TOUR Setup 19 5 2 TOUR Operation 19 6 MODEL 21 7 TRACE 22 7 1 TRACE Memory 22 7 2 TRACE Operation 23 8 AF 23 9 OSD 24 DVR Mode 25 Controller Mode 1 Controller Setup Mode 26 2 Controller ID Setup 27 3 SERIAL Setup 27 4 DATA COPY 28 5 RESPONSE 29 6 PASSWORD 31 6 1 PASSWORD Setup 31 6 2 Applying Pass...

Page 3: ...manufacturer immediately Stop using the appliance if there appears to be any operational problem Immediately turn the power off to the appliance if there is any abnormal condition such as smoke or unusual smells Continuing to use the appliance under abnormal conditions may result in serious damage Always use the recommended power Using incorrect power source ratings may result in fire electric sho...

Page 4: ...Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area i...

Page 5: ... sub controllers including the master controller Camera control with the joystick zoom buttons and focus buttons Easy camera preset location setup and movement Camera control without an operator through automatic operation mode Different surveillance cameras may have different names for the same functions depending on the manufacturer Some functions may not be available for certain models If the S...

Page 6: ...iled connection map of the JUNCTION Box Controllers and external devices 1 General Connection Controller Connection Cable RS 485 422 Video Cable DVR Dome Camera DVR 255 max Dome Camera Dome Camera Dome Camera SVR 1630 255 max CCD Camera Remarks Junction Box ...

Page 7: ...omatic or manual after operating the camera see p 23 OSD Displays the camera OSD menu see p 24 FUNCTION Used to perform 2 functions or more at the same time see p 8 Some buttons in the camera setup section may not be supported or may be used differently depending on the camera manufacturer Please refer to the table below for the buttons supported by the major camera manufacturers SPD 1600 SPD 2200...

Page 8: ...Selects the DVR mode see p 25 CAMERA Enter camera number and press the CAMERA button to set the camera ID PTZ mode or set the channel DVR mode MONITOR Not used will be applied to F W in the future SPD 1600 SPD 2200 SPD 2500 PELCO D PANASONIC WV CS854A SAMSUNGELECTRONICS SCC 643 641 TRACE RUN F 1 TRACE RUN TRACE RUN TRACE RUN PATTERN TRACE RUN PATTERN TRACE RUN PATTERN 1 TRACE MEMORY F 2 TRACE MEMO...

Page 9: ... recording list PLAY MODE Used for recording and playing the DVR with the controller SVR 900 1620 only MENU The DVR menu is displayed in the DVR monitor MULTI Used for switching the DVR monitor from single screen playback mode to multiple screen playback mode AUTO displays the sequence of cameras connected to the DVR on the monitor ALRAM RESET Used for resetting the alarm and event display turning...

Page 10: ...O MULTI O O O O AUTO O O O O ALARM RESET O O O O LIST O O PIP O O O DIGITAL ZOOM O O O O FREEZE O O SPOT O O O A B COPY O O O O LIVE PLAY BACK O Screen Selection Screen Selection RELAY O O O O II O O Jog PLAY MODE O Jog PLAY MODE O Jog O O Fast Forwarding PLAY MODE O Fast Forwarding PLAY MODE O O O Pause PLAY MODE O Pause PLAY MODE O I Jog O Slow Playback PLAY MODE O Slow Playback PLAY MODE O ENTE...

Page 11: ...the camera left 4 Tilt right Right button Moves the camera right 5 Turn stick clockwise Performs telephoto zoom 6 Turn stick counter clockwise Performs wide zoom SLOW Sets the camera movement up down left and right speed slow FAST Sets the camera movement up down left and right speed fast 7 Junction Box Joystick Camera Control Button Power Input Connector Junction Box Connector Front DIP Switch PT...

Page 12: ...when entering numbers with the number pad ID Shows the current controller ID If the ID is 1 it acts as the master controller If the ID is 2 or higher it acts as a sub controller Sub controllers cannot be used independently without a master controller Always assign a unique ID to ensure that the controller IDs do not conflict with each other SPD SPD 1600 SPD 2200 SPD 2500 SamsungTechwinCo Ltd PTZ C...

Page 13: ...oystick Camera Control Button The joystick can be used to control the camera s left and right pan and up and down tilt movements The joystick can be used to control camera zoom functions Camera wide zoom Camera telephoto zoom ...

Page 14: ...ther controller buttons The SLOW FAST button can be used to adjust movement speed for models without a joystick 6 Camera Zoom Control Press the ZOOM W T button to control zoom wide and zoom telephoto ZOOM W Zoom Wide ZOOM T Zoom Telephoto 7 Camera Focus Control Press the FOCUS button to control camera focus FOCUS Focus gets nearer FOCUS Focus gets further The FOCUS button can be used as the ENTER ...

Page 15: ...ivate the SETUP SYSTEM menu Press the 1 button to activate the PTZ SETUP 1 menu Press the button to activate the PTZ SETUP 2 menu SETUP SYSTEM 1 PTZ 2 DVR 3 CONTROLLER Press Numeric Key PTZ SETUP 1 1 PRESET 2 SWING 3 GROUP 4 TOUR Press Numeric Key PTZ SETUP 2 1 MODEL 2 TRACE 3 AF Press Numeric Key Models supported Models supported Menu Menu TOUR SPD series PRESET SPD series PELCO D PANASONIC SAMSU...

Page 16: ...tton to move the camera to the preset location If the number entered is not within the selectable range the last entered number is taken as the first number The selectable range for each camera model is as follows SPD 1600 2200 2500 1 64 PELCO D 1 80 Certain numbers have special functions other than preset 33 PRESET FLIP COMMAND 97 PRESET RANDOM SCAN 98 PRESET FRAME SCAN 99 PRESET AUTO SCAN See th...

Page 17: ...d ending point Can be set to 1 99 seconds Press the ENTER button to finish the setup takes 2 or 3 seconds to finish The Swing function cannot be set if an unassigned number or a number outside the selectable range is entered Over 2 PRESET locations have to be set before setting SWING 3 2 SWING Operation At the initial screen press the Swing button Press the 1 and 2 buttons to perform the Swing fun...

Page 18: ...Camera Preset ID for assigned location SPEED Area movement speed Can be set from 1 64 see p 35 STOP Stop time at the starting point and ending point Can be set to 1 99 seconds Press the ENTER button to move to the setup page for the next location Press the Group button to finish the Group Setup The Group function cannot be set if an unassigned number or a number outside the selectable range is ent...

Page 19: ...D series 5 1 TOUR Setup At the PTZ SETUP 1 menu press the 4 button see p 15 Press a Group number to add to the Tour Up to 6 Groups can be added Press the ENTER button to finish the setup 5 2 TOUR Operation At the initial screen press the Tour button The Tour function is performed The TOUR operation is only available for an SPD series TOUR SETUP 1 GROUP NUM 1 6 Enter Tour Set ...

Page 20: ... 20 PTZ Mode GROUP 1 TOUR GROUP 3 ...

Page 21: ...L SETUP PTZ ID 0 0 MODEL NONE Model Change PTZ MODEL SETUP PTZ ID 1 1 MODEL SPD Press a number in the number pad to set the PTZ camera ID The camera model type saved in EEPROM is displayed on the LCD monitor when changing camera ID When entering 1 Press the and buttons on the number pad to change the camera type SPD 1600 2200 2500 PELCO D PANASONIC WV CS854A and SAMSUNG ELECTRONICS SCC 643 types c...

Page 22: ...control buttons to perform the camera movement to input Allowed movements are horizontal movements pan vertical movements tilt zoom and focus controls Press the ENTER button to stop camera movement input Maximum length for movement memory is approximately 60 105 seconds This may vary according to free memory space Movement memory length may be shorter if the camera movement is more complicated Pre...

Page 23: ...s the button see p 15 Press the 3 button to move to the AF Setup screen Press the 1 button to automatically adjust the focus after camera operation Press the 2 button to disable automatic focus adjustment after camera operation Auto Focus Setup is also available in the OSD menu of the camera connected It is recommended that you set up the AF function through the camera OSD menu PTZ SETUP 2 1 MODEL...

Page 24: ...rsor right I Moves the menu cursor left II Moves the menu cursor up Moves the menu cursor down Joystick Use the joystick to move the menu cursor up down left and right Applies to SPD PELCO D and Samsung models only Joystick or other button inputs cannot be used for camera operation when the camera menu is displayed on the monitor PRESET SWING GROUP and TRACE functions can be set in the OSD menu of...

Page 25: ...e SVR 900 1620 system ID must be set to be the same as the controller DVR ID Menu System Setup Com Port Setup SYSTEM ID When connecting to an SVR 1630 the SVR 1630 keyboard control address must be set to be the same as the controller DVR ID Menu System Setup Misc Also for the SVR 1630 COM2 RS422 485 menu Menu System Setup Serial Port Device must be set to SCC 3000 and Interface to RS 485 and for t...

Page 26: ... button to activate the Controller SETUP 3 menu At the Controller SETUP 1 Controller SETUP 2 or Controller SETUP 3 menu press a menu number to open a setup menu SETUP SYSTEM 1 PTZ 2 DVR 3 CONTROLLER Press Numeric Key CONTROLLER SETUP1 1 CONTROLLER ID 2 SERIAL 3 COPY Press Numeric Key CONTROLLER SETUP2 1 RESPONSE 2 PASSWORD Press Numeric Key CONTROLLER SETUP3 1 PRIORITY 2 DEFAULT 3 F W UPDATE Press...

Page 27: ...button to activate the Serial 1 PORT Setup screen PTZ camera DVR connection PORT Press the 2 button to activate the Serial 2 PORT Setup screen reserved PORT The value displayed at step indicates the current setup value The BAUD RATE DATA BIT STOP BIT PARATY BIT for PORT 2 which connects to the sub controller are fixed and cannot be changed The PORT Setup screen will be displayed Press the number f...

Page 28: ...utton to return to the previous menu CONTROLLER SETUP1 1 CONTROLLER ID 2 SERIAL 3 COPY Press Numeric Key Enter ID Set 2 16 DATA COPY SUB CONTROL ID 0 Press Numeric Key DATA COPY Do you want to COPY 1 YES 2 NO SUB ID 2 Press Numeric Key DATA COPY Wait a Minute DATA COPYING SUCCESS The DATA COPYING SUCCESS message appears when data copying is complete The DATA COPYING FAIL message appears if data co...

Page 29: ...he change Press the 2 button to set the controller RESPONSE setting to OFF The master controller display shows the setup screen for the number of the connected sub controller Press the 1 4 button to set the number of the desired sub controller The controller automatically restarts to apply the changed settings after entering the number 1 Sets the number of sub controllers to 4 including the master...

Page 30: ...s OFF HALF DUPLEX FULL DUPLEX HALF DUPLEX FULL DUPLEX Always OFF 5 3 SPD 2500 DIP Setup ON OFF DIP SW 1 Not used DIP SW 2 Reserved DIP SW 3 RESPONSE Setup DIP SW 4 Factory default Always OFF Always OFF Always OFF RESPONSE ON Setup RESPONSE ON Setup RESPONSE ON Setup 5 2 SPD 2200 DIP Setup ON OFF DIP SW 1 RESPONSE Setup FULL DUPLEX HALF DUPLEX DIP SW 2 Reserved DIP SW 3 DIP SW 4 Always OFF Refer to...

Page 31: ...activate the Password Setup screen Use the number pad to enter a 6 digit password The password verification screen will appear Re enter the same password The password will be saved The factory default password is Please change the password after installation CONTROLLER SETUP2 1 RESPONSE 2 PASSWORD Press Numeric Key PASSWORD SETUP 1 PASSWORD SETUP 2 MENU ON 3 POWER ON Press Numeric Key PASSWORD SET...

Page 32: ...wer At the Password Setup screen press the 3 button Press the 1 button to ask for a password every time the appliance is powered on Press the 2 button to skip asking for a password 6 4 Entering Password If a password is set the password has to be entered every time the appliance is powered on or before entering the setup menu At the screen as illustrated on the right enter the password set at step...

Page 33: ...the DVR Restriction Setup menu Use the controller button to set the menu ID ID of the assigned sub controller Left 000 255 The currently selected restriction ID Right 000 000 ID to be assigned I Moves items left and right 2 16 Enters ID number ESC Moves to the upper menu ENTER Finishes setup CONTROLLER SETUP3 1 PRIORITY 2 DEFAULT 3 F W UPDATE Press Numeric Key PRIORITY SETUP 1 PTZ ID LIMIT 2 DVR I...

Page 34: ...the button twice see p 26 Press the 2 button to open the Default Setup screen Press the 1 button to change the controller setup values to the default values and restart the controller Press the 2 button to cancel the process CONTROLLER SETUP3 1 PRIORITY 2 DEFAULT 3 F W UPDATE Press Numeric Key DEFAULT SETUP DEFAULT SET NOW 1 YES 2 NO Press Numeric Key ...

Page 35: ...etup value Degrees second Setup value Degrees second Setup value Degrees second Setup value Degrees second 1 0 8 33 23 1 0 8 33 23 2 1 0 34 24 2 1 0 34 24 3 1 5 35 25 3 1 5 35 25 4 2 0 36 26 4 2 0 36 26 5 2 5 37 27 5 2 5 37 27 6 3 0 38 28 6 3 0 38 28 7 3 5 39 29 7 3 5 39 29 8 4 0 40 30 8 4 0 40 30 9 4 5 41 35 921 19 Tm0 1 41 1155 37 ...

Page 36: ...ction Box and External Devices JUNCTION BOX SUB JUNCTION BOX RX and TX RX and TX must be short circuited SVR 430 900 1620 connection SVR 1630 connection PTZ connection RX DATA RX DATA JUNCTION BOX When connecting with an SVR 1630 only SPD series PTZ cameras can be employed When controlling a PTZ camera via an SVR 1630 there is a delay and the response may be slow When controlling a PTZ camera with...

Page 37: ...X RS 485 PORT1 3 RX RS 485 PORT1 4 TX PORT1 5 TX PORT1 6 7 RX RS 485 PORT2 8 RX RS 485 PORT2 9 TX PORT2 10 TX PORT2 11 GND 12 RX RS 485 PORT3 13 RX RS 485 PORT3 14 TX PORT3 15 TX PORT3 4 RS 232C Pin Layout D_SUB_MALE Terminal Name 1 2 RX 3 TX 4 5 GND 6 7 8 9 5 1 15 11 1 5 6 9 ...

Page 38: ...t Zoom Sub Keyboard Flow control connected with Master Keyboard Auto Surveillance Tour Group Swing Preset Operating temperature Humidity 0 40 10 75 Storage temperature Humidity 5 55 10 95 Weight 2kg Dimension 400mm X 180mm X 45mm Without Joystick height 6 RS 485 422 Specifications 7 Junction Box DIP Switch Type Asynchronous Serial 1 START BIT 8 DATA BIT NO PARITY 1 STOP BIT Transmission method HAL...

Page 39: ... 201 902 0429 SAMSUNG TECHWIN MOSCOW OFFICE LENNINGRADSDY PR KT 37A KORP 14 RUSSIA 125167 MOSCOW TEL 7 095 258 9296 9298 FAX 7 095 258 9297 SAMSUNG OPTO ELECTRONICS UK LTD Samsung House 1000 Hillswood Drive Hillswood Business Park Chertsey Surrey KT16 OPS TEL 44 0 1932 455 308 FAX 44 0 1932 455 325 TIANJIN SAMSUNG OPTO ELECTRONICS CO LTD 7 Pingchang Rd Nankai Dist Tianjin P R China Post Code 30019...

Reviews: