Samsung S-NET mini MST-S3W User Manual Download Page 1

Air Conditioner

user manual

E DB98-30577A(3)

S-NET mini

MST-S3W
MST-S3WU

imagine

 the possibilities

Thank you for purchasing this Samsung product. 

MST-S3W_IB_E_30577-3.indd   113

2011-07-26   오전 9:48:03

Summary of Contents for S-NET mini MST-S3W

Page 1: ...Air Conditioner user manual E DB98 30577A 3 S NET mini MST S3W MST S3WU imagine the possibilities ThankyouforpurchasingthisSamsungproduct ...

Page 2: ...oduct Do not connect power cable to a communication terminal Potential risk of fire or explosion Consult the place of purchase or a contact center to disassemble or repair the product Potential risk of unit malfunction water leakage electric shock or fire Contact service center or dealer for installation Potential risk of fire or damage to the product Do not use Benzene Thinner or Clorox They may ...

Page 3: ...he product avoiding direct sunlight or heater especially water Potential risk of electric shock or poor air conditioning Never use a damaged power plug power cable or loosened power receptacle Potential risk of fire or electric shock Do not give excessive shock to the air conditioner Potential risk of fire or unit malfunction Do not yank the power cable and touch the power plug with wet hands Pote...

Page 4: ...or Unit Control Menu 20 Viewing by Icon 24 Viewing by List 25 Viewing by Full Screen 26 Controlling Indoor Units 28 Setting Up the Temperature Limit 32 Enable Disable Temperature Limit in Cool Mode 34 Enable Disable Temperature Limit in Heat Mode 35 Operate Mode Limits Setup 36 Indoor Unit Control in Exclusive Cooling Mode 38 Indoor Unit Control in Exclusive Heating Mode 39 Controlling Ventilators...

Page 5: ... Security Setup Menu 77 Tracking 78 Tracking Menu 78 Execute Tracking 82 View DVMInformation 86 View DVM Information 86 View Individual Detailed Information 87 View Error Log 88 View System Log 89 Deleting All System Logs 90 H WSetup 91 H W Setup Menu 91 Date Time setup 92 Brightness Control 93 Volume Control 94 IP Setup 95 View Version 96 Stylus Adjustment 97 System Management 98 System Managemen...

Page 6: ...enu Soft keyboard button Press this button to use the soft keyboard to enter text or number Lock button Restricts other people s access by using password Power LCD Backlight button Turn On Off the power and the LCD backlight Power indicator Red Indicates on off status Note For the longer use of your LCD screen will automatically switch to screensaver LCD backlight off if there has not been any inp...

Page 7: ...rd slot Insert SD card in to save or load data USB Host port Connect with other products set as device BottomView RS232 communication terminal For OS Debugging Connect with other RS232 communication device LAN port Connect with DMS Digital input terminal Connect with devices which outputs digital signal Ex Fire sensor 485 communication port Connect with 485 communication terminal on Centralized co...

Page 8: ...NET mini Connecting S NET mini with DMS Type You can control up to 4 DMS and 256 indoor units by using S NET mini a b c S NETminiconnectionisonlypossiblein1typeamong3types IfyouconnectS NETminiin a type youcannotconnectDMStoCentralizedcontroller IfyouconnectS NETminiin b type youcannotconnectCentralizedcontrollerto Transmitter IfyouconnectS NETminiin c type youcannotconnectS NET3toDMS Caution Cent...

Page 9: ...icator turns red If the Error indicator has turned red check the power and communication cable connection Checking the Connection Connection with DMS Make sure LAN cable is correctly connected to the LAN port Make sure power terminal is correctly connected Connection with Centralized controller Transmitter Make sure communication cable is correctly connected to 485 communication terminal Check the...

Page 10: ... air conditioning system Outdoor unit Hauzen ERV Energy saving Refresh Value Up Ventilating system using heat exchange function Terms Used in S NET mini S NET mini can remotely control the temperature operation mode fan speed on indoor units connected to DMS Centralized controllers and Transmitters Indoor Unit Control Interface with Lower Level Controller S NET mini is an integrated management sys...

Page 11: ...6 F in Heat mode Operation mode selection Auto Cool Dry Fan and Heat ERV mode selection Auto HeatEx ByPass and Sleep Remote control restriction Enable Disable Zone Management S NET mini can control indoor units conveniently by using zone management and changing the name of Zone Indoor unit Zone Indoor unit name can be maximum 16 letters long Special character or symbols cannot be used in a name Ea...

Page 12: ...sor related error Other errors Outdoor unit Outdoor unit communication error Piping inspection error Outdoor unit sensor related error Other outdoor unit related errors Communication Error such as the Centralized Controller Option device related communication error In System log management you can check the history and it can be shown maximum 512 cases If the number of cases exceeds 512 only the l...

Page 13: ...Management S NET mini have the following system setup functions Communication Setup Setting the method of communication System Initialization Initializing all the information DMS IP Setup and Update data When S NET mini communicates with DMS you set the IP without tracking and renew the install information and status information Synchronize Time When S NET mini communicates with DMS there must not...

Page 14: ...ay appears select Centralized controller Transmitter or DMS They should be connected to S NET mini before starting the system 2 Tap Apply Selected communication equipment will be applied and the S NET mini will restart Starting S NET mini 1 2 ...

Page 15: ...lus pen to tap center of the cross Tap from 1 to 5 in order as shown in the above figure 1 2 5 3 4 DonotusesharpobjectstotouchtheLCDscreen LCDscreencanbedamaged Usingfingerorotherdullobjecttopressthecrosswillresult incorrectscreencalibration Styluspenisnotincludedinapackage Caution ...

Page 16: ...on the screen after calibration Changed setting will be applied and S NET mini will restart If you want to stay with the previous setting wait 30 seconds without touching the LCD and the buttons Getting Started Continued ...

Page 17: ...be connected to S NET mini for communication Be aware of the fact that the communication cables for Centralized controller C1 C2 have polarity 2 Execute tracking S NET mini communicates with Centralized controller and the Transmitter to bring all the information on indoor units and outdoor units Indoor unit control and other menu can be used after tracking Refer to Tracking Execute Tracking for in...

Page 18: ...he IP See pages 101 102 4 Execute tracking S NET mini communicates with DMS to bring all the information on indoor units and outdoor units Indoor unit control and other menu can be used after tracking Refer to Tracking Execute Tracking for instructions on tracking See pages 84 85 5 Synchronize the time on S NET mini and DMS S NET mini and DMS should have synchronized time to operate correct indoor...

Page 19: ...anagement Security setup Tracking View DVM information H W setup System management 2 Indoor unit error indicator 3 Date Time indicator 4 DMS Connection Status DMS not connected Gray DMS connected Blue DMS Error Orange 5 Emergency Stop Status Emergency Stop Normal operation 6 S NET mini program version display 6 5 4 ...

Page 20: ...e control restriction on selected indoor units 6 Temperature limits Set lower upper limit temperature in Cool Heat mode on selected indoor units Today s schedule View today s applied schedule on selected indoor units Filter reset Turn off the filter warning on selected indoor units Operate mode limits Sets operation mode limit on selected indoor units 7 Zone View total 8 Zone name list 9 Indoor un...

Page 21: ...on selected indoor units 6 Remote Control Sets remote control restriction on selected indoor units 7 Temperature limits Set lower upper limit temperature in Cool Heat mode on selected indoor units Today s schedule View today s applied schedule on selected indoor units Filter reset Turn off the filter warning on selected indoor units Operate mode limits Sets operation mode limit on selected indoor ...

Page 22: ...Cool mode on selected device Temperature limit in Heat mode Enable Disable temperature limit in Heat mode on selected device 7 Remote control Sets remote control restriction on selected device 8 Temperature limits Set lower upper limit temperature in Cool Heat mode on selected device Humidity Set the desired humidity on selected device Filter Reset Turn off the filter warning on selected device Op...

Page 23: ...able temperature limit in Cool mode on selected device Temperature limit in Heat mode Enable Disable temperature limit in Heat mode on selected device 8 Remote control Sets remote control restriction on selected device 9 Temperature limits Set lower upper limit temperature in Cool Heat mode on selected device Humidity Set the desired humidity on selected device Filter Reset Turn off the filter war...

Page 24: ... temperature of rooms with indoor units Desired Temperature Indicates set temperature by user Operation Mode Indoor Unit Auto Cool Heat Fan ERV HeatEx Auto ByPass Sleep Temperature limit in Cool Heat mode Enabled Setting Today s schedule Remote Control restriction level 2 Exclusive Cooling Exclusive Heating Blue Gray Purple Dark Gray Pink White On Off Network Error Filter Warning Error Unassigned ...

Page 25: ...cates set temperature by user Operation Mode Indoor Unit Auto Cool Heat Fan Dry ERV HeatEx Auto ByPass Sleep Fan speed Air flow Indicates the fan speed and the air flow direction of the indoor unit Additional information Indicates temperature limit in Cool Heat mode and remote control restriction Tap Indoor unit control on the Main menu 1 Blue Gray Purple Dark Gray Pink White On Off Network Error ...

Page 26: ...26 Viewing by Full Screen Indoor Unit Control Continued Tap Indoor unit control on the Main menu 1 Tap View all from the indoor unit control menu 1 ...

Page 27: ...ose Close the full screen window 2 Tap on option from the full screen window to check the status of all indoor units View name Name of the indoor unit View temp Shows current temperature View RC R Indicates remote control restriction status C Indicates temperature limit in Cool Heat mode Background color Different color indicates different indoor unit status 2 Blue Gray Purple Dark Gray Pink White...

Page 28: ...ntrol window Tap the indoor unit again to deselect Note When Basic operation Auto Cool Heat Fan Dry and advanced function good sleep Timer is selected desired temperature on the remote control and the S NET mini can be different Advanced function will be displayed as Auto on your S NET mini All the advanced function will be canceled when you control the air conditioner with S NET mini Each indoor ...

Page 29: ...ature when Cool or Dry mode is in progress If the temperature limit in Heat mode is on you cannot set the desired temperature higher than upper limit temperature when Heat mode is in progress If you are controlling ERV tapping the Power on the indoor unit control window will not turn off the actual power but it will stop the advanced operations such as Auto Cool Heat which is not related to ventil...

Page 30: ...O O Heat O O O Fan O O O Dry O X X You cannot set the fan speed on Fresh Duct and ERV Fan speed of the AHU will be fixed on High MINI AHU does not support Auto fan speed When the fan speed of MINI AHU is set to Auto the fan speed will be set to High and when it operates in Dry the fan speed will be set to Low If the EHP GHP Global 4way is operating in Auto Dry mode fan speed will be set to Auto an...

Page 31: ...ralizedcontroller transmitter rememberspreviousdesiredtemperature fanspeedand airflowdirectionvalueforeachoperationmode However indoorunitsinstalledundertheDMSdonot savepreviouscontrolinformation Dependingonthemodelofindoorunit horizontal allairflow controlmaynotbepossible Inthiscase theairflowwillbe automaticallychangedasverticalorfixedairflowdepending onthebasicoperationspecificationoftheindooru...

Page 32: ...splay The indoor unit name will be displayed on the Selected Indoor unit display Current status of last selected indoor unit will be displayed on the Indoor unit control window Tap the indoor unit again to deselect 3 Tap Temperature limits setup 1 2 3 Someofthedevicesmaynotsupporttemperaturelimitssetup Temperature limits setup is only available for the devices that can control desire temperature C...

Page 33: ...d for a user to set the desired temperature out of the lower upper limit temperature range with wired wireless controller and indoor unit panel Note Youcansetthelowerlimittemperaturebetween18 C 30 C 65 F 86 F Youcansettheupperlimittemperaturebetween16 C 30 C 61 F 86 F 6 4 5 ERV ERV and Fresh duct does not have Temperature Limit function If you set the temperature limit after selecting all the devi...

Page 34: ...button will be changed to and then temperature limit in Cool mode will be enabled The set temperature limit which set in cool dry mode is enabled You cannot set the desired temperature lower than the temperature limit which set in cool dry mode After selecting indoor unit and enabling the temperature limit in Cool mode will be displayed on the indoor unit display window Even if the user set the de...

Page 35: ... The status of button will be changed to and then temperature limit in Heat mode will be enabled When Heat mode is in progress Temperature limit in Heat mode is enabled You cannot set the desired temperature higher than the upper limit temperature After selecting indoor unit and enabling temperature limit in Heat mode will be displayed on the indoor unit display window When Heat mode is in progres...

Page 36: ...nits under selected zone will be displayed on Indoor unit display window 2 Select one or more indoor units from the indoor unit display window The indoor unit name will be displayed on the Selected Indoor unit display Current status of last selected indoor unit will be displayed on the Indoor unit control window Tap the indoor unit again to deselect 1 2 3 ...

Page 37: ...er select Auto Heat or Heat mode with wired wireless remote control the operation mode of indoor unit will be changed to Cool mode Exclusive Heating Fan Forces indoor units to operate Exclusive Heating only In Exclusive Heating Fan mode if the user select Auto Cool Cool or Dry mode with wired wireless remote control the operation mode of indoor unit will be changed to Fan mode Exclusive Heating He...

Page 38: ...or unit with icon in current status from the indoor unit display window The indoor unit name will be displayed on the Selected Indoor unit display Current status of last selected indoor unit will be displayed on the Indoor unit control window Tap the indoor unit again to deselect It is impossible to select Auto Heat mode If the indoor unit is in Exclusive Cooling mode Indoor unit control method is...

Page 39: ... in current status from the indoor unit display window The indoor unit name will be displayed on the Selected Indoor unit display Current status of last selected indoor unit will be displayed on the Indoor unit control window Tap the indoor unit again to deselect It is impossible to select Auto Cool Dry mode if the indoor unit is in Exclusive Heating mode Indoor unit control method is same as the ...

Page 40: ...l Cool Fan Dry Fan Auto Cool Fan Fan Dry Exclusive Heating Heat Auto Heat Heat Fan Heat Fan Auto Fan Heat Fan Fan Off On Setting Controlling Exclusive Cooling Exclusive Heating indoor unit with wired wireless remote controller The operation mode will be changed automatically within 1 minute when you control Exclusive Cooling Exclusive Heating indoor unit with wired wireless remote controller Auto ...

Page 41: ...r to be controlled from the Indoor unit display window The name of the ventilator will be displayed on the Selected Indoor unit display Current status of last selected ventilator will be displayed on the ERV unit control window Tap the ventilator again to deselect 1 2 Eachventilatorshouldbeturnedonsincedetailedcontrolis notpossiblewhenitisoff However RemotecontrolandFilter Resetfunctionsareallowed...

Page 42: ...ventilator is off 4 Select an operation mode Select from four available modes HeatEx Auto ByPass Sleep If you are controlling ERV tapping the Power on the ERV unit control window will turn off the actual power If the power turns off you cannot control the operation modes such as Auto Cool Heat Caution 3 4 5 ...

Page 43: ...se communication device are connected to centralized controller transmitter remembers previous desired temperature fan speed and air flow direction value for each operation mode However indoor units installed under the DMS do not save previous control information Low swing High swing Turbo Heat Exchange O O O Auto O O O By Pass O O O Sleep O X X Fan Speed Operation mode ...

Page 44: ...t display Current status of last selected indoor unit and ERV will be displayed on the Indoor unit control window and ERV unit control window Tap the device again to deselect Indoor unit control method is same as the order of Controlling Indoor Units see pages 28 31 Ventilator control method is same as the order of Controlling Ventilators see pages 41 43 1 2 Unsupportedoperationwillbeignoreddepend...

Page 45: ...w The name of device will be displayed on the Selected Indoor unit display Current status of last selected device will be displayed on the Indoor unit control window or ERV unit control window Tap the device again to deselect 3 Tap Filter Reset Filter warning of selected device will be canceled 1 2 Ifyoutap FilterReset afterselectingdevicewhichhavenotgotfilterwarning itwillnotbecontrolled Caution ...

Page 46: ...lay window The name of device will be displayed on the Selected Indoor unit display Current status of last selected device will be displayed on the Indoor unit control window or ERV unit control window Tap the device again to deselect 3 Tap Individual wired wireless remote controller can control the devices If you enable wired wireless remote control after selecting the device will be gone from cu...

Page 47: ...rol window or ERV unit control window Tap the device again to deselect 3 Tap Individual wired wireless remote controller cannot control the devices You may only control the devices from the S NET mini indoor unit control menu If you disable wired wireless remote control after selecting the device will be displayed on current status of device in indoor unit display window To enable wired wireless r...

Page 48: ...ntrol window Tap the indoor unit ERV again to deselect 2 Check today s schedule when the list appears You may check the applied time indoor unit On Off status schedule name desired temperature operation mode ERV operation mode and remote control restriction Tap OK after checking the schedule and you will return to Indoor unit control menu Select single indoor unit or ERV to check today s schedule ...

Page 49: ...Current status of last selected device will be displayed on the Indoor unit control window or ERV unit control window Tap the device again to deselect When there is a device that supports humidity control within the selected devices and if it is operating in the mode that allows the function Humidity button will be activated Ex When MINI AHU is on and operating in Heat mode 3 Tap Humidity You can ...

Page 50: ...lected zone will be displayed on Indoor unit display window 2 Select one or more devices to be controlled from Indoor unit display window The name of device will be displayed on the Selected Indoor unit display Current status of last selected device will be displayed on the Indoor unit control window or ERV unit control window Tap the device again to deselect 1 2 3 6 5 7 4 ...

Page 51: ...tion Human Sensor button will be activated If you tap the Human Sensor button function will turn on off 6 When there is a device that supports SPI function SPI button will be activated If you tap the SPI button function will turn on off 7 When there is a device that supports OA Intake function OA Intake button will be activated If you tap the OA Intake button function will turn on off Cooling Heat...

Page 52: ...hat supports Out Cool function within the selected devices and if it is operating in the mode that allows the function Out Cool button will be activated If you tap the Out Cool button function will turn on off Device that supports OA Intake Humidification Humidification level control Out Cool function MINI AHU Advanced function of the device may or may not be supported depending on the option sett...

Page 53: ...nication device No Remarks 1 Return to main menu 2 Schedule list Repeat Name Apply 3 Create new schedule Edit schedule Delete schedule Apply selected schedule Stop selected schedule Stop all schedules No Remarks 4 Open saved schedule in CSV file 5 Save schedule in CSV file 6 Check one day daily weekly schedule settings On Off Temperature Mode ERV mode Allow use of remote control 7 Shows schedule p...

Page 54: ...le on the Schedule management menu 2 Set up the repeat option from Schedule type setup window You may select either Repeat weekly Repeat daily or One day 3 Tap OK from the Schedule type setup window New schedule menu will pop up with the selected repeat option To cancel the selected repeat option tap Cancel 1 3 2 ...

Page 55: ...ne To cancel the Schedule period tap Cancel Note Schedule name can be maximum 16 letters long Special character or symbols cannot be used in a name If you select Repeat daily or Repeat weekly default schedule period of 1 year from the current time of S NET mini will be set If you select one day today will be selected as a default schedule day If you select No time limit time limit will not be appl...

Page 56: ...th and then select the day Exception day can be setup with the schedule period To cancel the Exception day select the exception day from the list and tap Deselect 10 Tap OK when the setting is done Exception days will be omitted from the applied schedule To cancel the exception days tap Cancel Note Exception days cannot exceed 365 days 9 ...

Page 57: ...he indoor unit list Tap Cancel all to cancel the selection indicates indoor unit and indicates ERV 13 Tap OK when the setting is done To cancel indoor unit selections tap Cancel Note If you want to set a schedule after connecting S NET mini to DMS schedule setting is only possible on indoor units under the same DMS If you set same schedule to indoor units under different DMS the message as follows...

Page 58: ...et up weekly repeat option 16 Tap OK when the setting is done To cancel adding event tap Cancel Note Youcansetmaximum10eventsperscheduleinaday Dailyrepeat Maximum10 Weeklyrepeat Maximum10perday Todeleteevent selectaneventtobedeletedandtap Deleteevent 16 YoucanselecttheModefromAuto Cool Heat Fan DryandOff Off willonlyaffectERV devicefromoperatinginadvanced operations suchasAuto Cool Heat whenitisin...

Page 59: ...t 18 Enter event name and information You may use soft keyboard to enter an event name and information See pages 106 107 19 Tap OK to save the event Event will be saved with the previously chosen event name To cancel saving tap Cancel Note Ifyouwanttoopenasavedevent tap Open Theopenunitisoneday Alsoincaseofeveryweekschedule openinonedayunit 17 18 19 ...

Page 60: ...enu 1 Select a schedule to be edited from the schedule menu If the schedule is in progress tap Stop to stop the schedule before editing 2 Tap Edit Edit schedule when the Editing Schedule display window appears Editing schedule method is same as Creating New Schedule See pages 54 59 1 2 ...

Page 61: ...lect a schedule to be deleted from the schedule menu If the schedule is in progress tap Stop to stop the schedule before deleting 2 Tap Delete 3 Tap OK from the Delete schedule list window Selected schedule will be deleted To cancel deleting schedule tap Cancel 2 3 1 ...

Page 62: ...ed schedule should be in Stop state 2 Tap Apply Selected schedule will change its status to Run state Note Ifthereisanindoorunittooperatetodayonthe today sappliedschedule willbedisplayedontheIndoor unitcontrolwindow Alsoyoucancheckschedulethrough Today sschedule intheIndoorunitcontrolwindow Schedule Management Continued 1 2 ...

Page 63: ...dules Tap Schedule management on the Main menu 1 Select a schedule to be stopped from the schedule menu Selected schedule should be in Run state 2 Tap Stop Selected schedule will change its status to Stop state 1 2 ...

Page 64: ...64 Stop all Schedules Schedule Management Continued Tap Schedule management on the Main menu 1 Tap Stop all from the schedule menu All the schedules in Run state will stop 1 ...

Page 65: ...ed If soft keyboard blocks the view you may drag soft keyboard out of the way You may use soft keyboard to enter a file name See pages 106 107 The file will be saved as CSV format automatically 4 Tap OK To cancel saving the schedule tap X Note Saving schedule function is only supported when Centralized controller Transmitter is selected as communication device 1 2 3 4 ...

Page 66: ...files in CSV format 2 Select a CSV file to be opened If soft keyboard blocks the view you may drag soft keyboard out of the way 3 Tap OK Selected schedule will be added to S NET mini To cancel opening the schedule tap X Note Opening schedule function is only supported when Centralized controller Transmitter is selected as communication device 3 1 2 ...

Page 67: ...ly status 2 Check the schedule from the schedule list You can check the weekly schedule settings 3 Tap Selected indoor unit to check the indoor units applied with the selected schedule 4 Tap Exception day to check the exceptional days Viewing Schedule Tap Schedule management on the Main menu 2 3 4 ...

Page 68: ...ed zone Zone Management 7 6 1 3 1 2 4 8 11 No Remarks 8 Rename selected zone indoor unit 9 Select all indoor units in selected zone 10 Deselect selected indoor unit 11 Open saved zone status 12 Save current zone status 13 Initialize zone structure 14 Move selected indoor unit to different zone 15 Remarks Saving OpeningzonefunctionisonlysupportedwhenCentralized controller Transmitterisselectedascom...

Page 69: ...69 Creating a New Zone Tap Zone management on the Main menu 1 Tap New zone from the zone management menu 2 New Zone will appear on the Zone list 1 ...

Page 70: ...nagement on the Main menu 1 Select a Zone to be deleted from the Zone management menu Selected zone with one or more indoor units cannot be deleted Move all the indoor units to other zone then proceed deleting 2 Tap Delete zone Selected zone will be deleted 2 1 ...

Page 71: ... name select a Zone only To change an indoor unit name select one indoor unit 3 Change the name of the zone indoor unit You may use soft keyboard to rename a zone indoor unit See pages 106 107 1 2 3 Zone Indoorunitnamecanbemaximum16letterslong Specialcharacterorsymbols cannotbeusedinaname Ifyouselectmultipleindoorunits youcannotrename them Zonenamecannotberepeated Caution ...

Page 72: ... 1 Select a zone to move up down You can select one zone at a time 2 Tap Up or Down to move selected zone indoor unit to desired location In indoor unit control zone will appear in edited order Zone Management Continued 1 2 Indoorunitscannotbemovedup down Caution ...

Page 73: ...more indoor units To select all the indoor units in indoor unit list select a zone and then tap Select all To deselect all selection tap Cancel all 3 Tap Move to different zone 4 When the other zone list appears select different zone where indoor unit will be move 5 Tap OK To cancel moving the indoor unit to a different zone tap Cancel Note Individual zone can contain maximum 64 indoor units 1 2 3...

Page 74: ...tinued Initialize Zone Management Tap Zone management on the Main menu 1 Tap Initialize from the Zone management menu 2 Tap OK It goes back to initial state before editing Zone management To cancel Initialize tap Cancel 1 2 ...

Page 75: ...he file and enter a file name You may use soft keyboard to enter name of the new zone See pages 106 107 The file will be saved as CSP format automatically 3 Tap OK Selected zone management will be saved as CSP file To cancel saving tap X Note SavingZonemanagementisonlysupportedwhen Centralizedcontroller Transmitterisselectedas communicationdevice 1 2 3 ...

Page 76: ... opening tap X Note Opening Zone management is only supported when Centralized controller Transmitter is selected as communication device Zone Management Continued Opening Zone Management Tap Zone management on the Main menu 2 1 IfindoorunitsofZoneinformationdoesnotmatchwiththe actuallyinstalledindoorunits properoperationmaynotbe possible Caution ...

Page 77: ...ee pages 106 107 3 Tap Apply changes New password will be applied Note Currentpassword newpasswordandverifyingpasswordhavetobeaccurate Initial password for S NET mini is 0000 1 2 3 No Remarks 1 Return to main menu 2 Authentication password current password new password verify password 3 Apply changes Ifyouforgetpassword youcannotchangethepasswordstatus optionorchangetoanewpassword Beconsideratewhe...

Page 78: ... Tracking Tracking Menu 1 1 Tap Tracking from the main menu 2 Enter the password when password authentication window appears 3 Tap OK Centralized controller Transmitter is set as communication device 2 3 ...

Page 79: ...nu window may appear different depending on the communication devices When DMS is set as communication device see pages 80 81 No Remarks 1 Return to main menu 2 Select a device for tracking Centralized controller Transmitter 3 Tracking start button ...

Page 80: ...80 Tracking Continued 1 1 Tap Tracking from the main menu 2 Enter the password when password authentication window appears 3 Tap OK DMS is set as communication device 2 3 ...

Page 81: ...indow may appear different depending on the communication devices When Centralized controller Transmitter is set as communication device see pages 78 79 No Remarks 1 Return to main menu 2 Select a tracking mode Group Individual 3 Tracking start button ...

Page 82: ...vice for tracking from the tracking menu You can select either Centralized controller or Transmitter 2 Tap Tracking start Tracking will start with selected device Tracking Continued Centralized controller Transmitter are set as communication device 1 2 IfS NETminiandDMS2areconnected youcannotselect Group mode Caution ...

Page 83: ...rol Zone management and Schedule management menu 5 Tap OK System will be configured with new information To disregard the tracking result tap Cancel 5 Beawarethatwhentrackingisinprogress someoftheinformationcanget missing Whenthetrackingresultisincorrectordoesnotshow checkthecommunication statusorcommunicationdeviceselection Itmaytakemaximum3minutesand30secondsfortrackingdependingonthe amountofinf...

Page 84: ...k information on representing indoor unit within a group assigned to S NET mini Individual mode Track information on all the indoor units connected 2 Tap Tracking start Tracking will start with selected device Tracking Continued DMS is set as communication device 2 1 ...

Page 85: ...the tracking result of indoor unit which is not using centralized controller It is not displayed in Indoor unit control Zone management and Schedule management menu 5 Tap OK System will be configured with new information To disregard the tracking result tap Cancel Note Be aware that when tracking is in progress some of the information can get missing When the tracking result is incorrect or does n...

Page 86: ...Information View DVM Information 1 Tap View DVM information on the main menu Check the View DVM information menu No Remarks 1 Return to main menu 2 Individual detailed information 3 Error log 4 System log 1 1 2 3 4 ...

Page 87: ...tter Indoor unit and Outdoor unit to be viewed You can check items and contents of the indoor unit Note You cannot check the individual detail information if you have selected Group from tracking mode selection You can view the detailed cycle information on DVM Plus 2 or DVM Plus 3 with the centralized controller MCM A202B and transmitter MIM B13B or higher version of those devices However the det...

Page 88: ...formation of the error log To delete all error logs tap Delete all See page 90 Note Maximum256errorlogscanbeshownonthelistifyousetcentralizedcontroller Transmitterascommunicationdevice AndifyousetDMSascommunication device maximum256errorlogsperoneDMScanbeshownonthelist Errorlogwillnotbevisibleifnetworkerroroccursorthesystemtrackingisin progress Selectall functionisonlyoperatedwhenyousetCentralized...

Page 89: ... Description 3 Select the system log from the list You can check the detailed information of the system log Note FollowinglogswillbesavedinS NETmini Tracking OperatingSchedule OpeningSchedule DeletingErrorLog InitializingZoneManagement OpeningZoneManagement ChangingIP ChangingCommunicationSetup SettingDMSIPandUpdatedata OperatingSystemInitialization ChangingTime DeletingSystemlog UpdatingS NETmini...

Page 90: ...u You can select to view Individual detailed information Error log and System log 2 Tap Erase all 3 Enter the password for authentication 4 Tap OK All system logs will be deleted Deleting system log will be recorded Deleting All System Logs Tap View DVM information on the Main menu 1 3 4 2 ...

Page 91: ...n the main menu Check the Hardware setup menu No Remarks 1 Return to main menu 2 Date Time setup 3 Brightness control 4 Volume control 5 IP setup 6 View version 7 Stylus adjustment H W Setup Menu 1 1 2 3 4 5 6 7 H W Setup ...

Page 92: ...year and tap or to select month and then select the day 3 Select AM or PM then tap or to set time 4 Tap Apply Selected date time will be saved To cancel date time setup tap Cancel Note You can set the date between January 1st 2000 and December 31st 2041 After PM 11 59 December 31st 2041 the date will be changed to January 1st 2000 2 3 4 1 ...

Page 93: ... 1 Tap Brightness control tab from the hardware setup menu 2 Tap or to set the screen brightness You can also move the scroll left or right to set the brightness 3 Tap Apply Selected brightness will be saved To cancel brightness control tap Cancel 1 2 3 ...

Page 94: ...nu H W Setup Continued 1 Tap Volume control tab from the hardware setup menu 2 Tap or to set the volume You can also move the scroll left or right to set the volume 3 Tap Apply Selected volume will be saved To cancel volume control tap Cancel 1 2 3 ...

Page 95: ...owing IP address If you select Use the following IP address you have to enter IP address Subnet mask and Gateway 3 Tap Apply Selected IP will bee saved To cancel IP setup tap Cancel 1 2 3 DynamicIPaddressconfiguration DHCP canbeselected whentheDHCPserverisconnectedtothenetwork IPsetin IPSetup isnottheIPofDMS EntertheIPof S NETminiwhichisdifferfromDMSIP Caution ...

Page 96: ...96 ViewVersion Tap H W setup on the Main menu H W Setup Continued 1 Tap View version tab from the hardware setup menu 2 Check the current version You can check the program and OS version 1 ...

Page 97: ...djustment tab from the hardware setup menu 2 Tap Start 3 Use stylus to tap the center of the cross when the stylus adjustment window appears You have to follow the cross and repeat this step few times 3 Tap H W setup on the Main menu 1 2 ...

Page 98: ... System setup menu No Remarks 1 Return to main menu 2 Communication setup 3 System initialization 4 DMS IP setup Update data 5 Synchronize time System Management Menu 1 1 2 3 4 5 DMSIPSetupandSynchronizeTimefunctionareonly supportedwhenDMSissetascommunicationdevice Caution ...

Page 99: ...om the System setup menu 2 Select either Centralized controller Transmitter or DMS 3 Tap Apply 4 Enter the password for authentication 5 Tap OK Selected device will be applied and S NET mini will restart To cancel communication setup select other tab or tap Menu to return to main menu 1 2 3 4 5 ...

Page 100: ...enu 2 Tap Apply 3 Enter the password for authentication 4 Tap OK System will be initialized and S NET mini will restart To cancel system initialization select other tab or tap Menu to return to main menu Note You need to select a communication device when system restarts For more detailed information refer to Getting Started See pages 14 18 1 3 4 2 ...

Page 101: ...cate continuously between S NET mini and DMS After DMS IP setting and password authentication it gets install information and status information from DMS and builds environment that can control indoor unit and devices 2 Enter DMS IP and DMS password when DMS IP setup Update data display window appears DMS password must be within 4 8 letters of English Number Consult DMS manager from DMS authentica...

Page 102: ...setting the DMS connection setup 4 From the authentication window enter the password 5 Tap OK DMS IP setup and Update data will be in progress after password authentication is done To cancel all DMS IP setup and Update data tap Cancel System Management Continued 4 5 3 ...

Page 103: ...ET mini screen Contents Detailed information Connecting to network Connecting to network Network connection failed Occurred an error or not connected to network Password authentication Authenticating password is in progress or already done Password authentication failed Failed to authenticate password Updating data Updating installation structure and status information Updating data failed Failed ...

Page 104: ... Setup According to selected time the standard time of connected DMS and S NET mini will be set in same time If DMS is not connected DMS time will not display To cancel synchronize time select other tab or tap Menu to return to main menu To synchronize time with DMS you must set DMS IP first See pages 101 103 IfthetimeofS NETminiandDMSarenotsame theschedulewilloperatebyDMStime Select Synchronizeti...

Page 105: ...t DMS re tracking the number of indoor outdoor units and the number of Centralized controller Transmitter 2 The warning will be displayed on bottom of S NET mini when DMS install information updated Setting of S NET is differ from one of DMS 3 To synchronize information tap Connection Update in DMS IP setup Update data menu 2 3 ...

Page 106: ...enter the text Using Soft Keyboard You will need Soft keyboard to input number or text Press Key Board button located on side of S NET mini Open Soft Keyboard Press Key Board button located on side of S NET mini while the soft keyboard is on the screen Close Soft Keyboard Move Soft keyboard Around the Screen Soft Keyboard 1 T Enter ...

Page 107: ...107 1 Tap the letter or number by using stylus pen Caps Lock To enter upper case letters or symbols Ins Insert letters Del Delete letters Other keys work same as ordinary keyboard Enter Text Number ...

Page 108: ...eck the IP for DMS Is the LAN connected to the DMS correctly Check the LAN is connected to the DMS correctly It is impossible to connect the DMS to S NET mini without LAN Consult a person in charge of network for further information Doesn t the DMS have any defect Check the status of the DMS Did you set the correct IP for S NET mini and the DMS Refer to H W setup IP Setup to check the S NET mini I...

Page 109: ...as polarity Check the centralized controller is turned on Is the centralized controller connected to the interface module correctly Check the power communication cable between the centralized controller and the interface module Indoor units are out of control Is LAN cable properly connected Check the LAN cable and the LAN indicator Are the indoor units connected to the DMS correctly Check the powe...

Page 110: ...ni display is not working Is the screensaver backlight off on Press any button or tap anywhere on the LCD Schedule is not operating at desired time Did you synchronize the time for S NET mini with DMS Set the correct time on S NET mini and synchronize time with DMS Sound is not working Did you check the volume control to make sure it is not in Low Refer to H W Setup Volume control to check and adj...

Page 111: ...permanent address on the Internet Dynamic IP Dynamic IP is a number which changes every time when computer or model has restarted Private IP This is a local IP which cannot be used for internet connection If you share internet connection through router internet sharing software or through OS you may check the Client IP and they will be similar to below number system 10 X X X 172 X X X 192 168 X X ...