TROUBLESHOOTING
* Self-Diagnosis Error Description
- When the Failure Condition occurs, the Compressor will immediately stop if the Compressor is running
and there will be a 5 minute standby. During the 5 minute standby, RPM signals will be ignored. That is,
even though the Inverter PBA receives the RPM signals, the Compressor does not work. It blinks every
second and there is 2 second off at the end of each cycle.
Protecting
Functions
LED
Blinking
Frequency
Remark
Normal
Operation
N/A
Starting
Failure
1. Short between COMP U,V, and W phase (CN102)
2. Short among IC3 Pins (No. #1~24)
3. Drop the IPM operating Voltage under DC 13.5V
4. Other cases, check the COMP, cycle, etc.
IPM Fault
Motor Position
Error
1. Open the COMP wire (CN102)
2. Bad condition of resistor R1(ex. Bad soldering)
3. Other cases, check the COMP, cycle, etc.
Motor Position
Error
1. Operating the locked rotor COMP within 5 second.
2. Operating the COMP under 1000 RPM more than
5 seconds.
3. Occur the huge change of input voltage in a
moment.
4. Other cases, check the COMP, cycle, etc.
Low Voltage
1. Drop the input voltage under AC106V. Short
resistor R514 (DC link resistor)
Over Voltage
1. Increase the input voltage over AC 310V
2. Short resistor among R511, R512 and R513 (DC
Link resistor)
LED blinking frequency depending on protecting functions If the same blinking, After 5 minutes, Follow the
Remarks