TROUBLESHOOTING
4-2-1. When Self-Diagnosis Error occurs
- The Display Panel shows the Sensor Error and, when the unit is plugged in and there are sensor errors,
the unit does not operate and Display bar related to the defective sensors keep blinking.
- When sensor defects occur during the operation, the unit keeps working. But, it shifts to the Emergency
Operation and it may not work properly. So, please check the unit according to the Self Diagnosis function.
MAIN PCB Connector
CN30 is inserted properly?
R Sensor is
normal?
Voltage between
MAIN PCB Connector CN30-"5"(ORG)
and CN30-"7"(GRY)?
Input Voltage at IC10
MICOM Pin# 23 is normal?
Start
PCB and Temp Sensor are normal.
Check the connector contact.
Connector contact defect /
Reconnect
Replace Temp Sensor
Check the wire connection
Check Soldering Defect & Short
No
No
NO(Value < 0.6V or Value > 4.6V)
No
Yes
Yes
Yes
Yes
Sensor MICOM/Connector #
R
Between Connector CN30-
"5"(ORG) and CN30-"7"(GRY)
Voltage : Between 4.6V ~ 0.6V
** Sensor Resistance Reading Location **
R : Between CN30 #5 and #7
** 0Ω : Short / ∞Ω : Open
Voltage at IC10 MICOM #
23 is the same as the value
Refer to Circuit Diagram
DATA1. Temp Table
ERROR CODE
1) When the R-Sensor is defective