Defrost Control From 6 to 11 hrs
Defrost Thermistor(502AT) 59
℉
(off)
Electrical Rating AC115V 60Hz 11.6 Amps
Maximum Current Leakage
0.25 mA
Maximum Ground Path Resistance 0.1Ohm
Energy Consumption kWh/mo.
Bimetal 104
℉(on)/
140
℉
(off)
Ambient Temperature
70
℉
90
℉
Refrigerator,
℉
34
�
46 34
�
46
Freezer,
℉
-11
�
7 -11
�
7
Run Time,%
�
40
�
60
Refrigerant Charge (R134a)
6.17 oz
Compressor(MK183C-L2U)
1032 Btu/hr
Compressor oil Freol
α
-15
Capillary tube(Dia, Length) 0.033
"
"
,130
"
"
Dryer Molecular Sieve XH-9
Clearance must be provided for air circulation
AT TOP 1
"
"
AT SIDES 1/8
"
"
AT REAR
1
"
"
RS2530, RS2630
PBA MAIN(RS2*11)
∙∙∙∙∙∙∙∙∙∙
DA41-00216A
PBA MAIN(RS2*21)
∙∙∙∙∙∙∙∙∙∙
DA41-00217B
PBA MAIN(RS2*30)
∙∙∙∙∙∙∙∙∙
DA41-00218C
PBA MAIN(RS2*31)
∙∙∙∙∙∙∙∙∙
DA41-00219D
PBA PANEL(RS2*11)
∙∙∙∙∙∙∙∙∙
DA41-00218A
PBA PANEL(RS2*21)
∙∙∙∙∙∙∙∙∙
DA41-00218B
PBA PANEL(RS2*30)
∙∙∙∙∙∙∙∙∙
DA41-00235A
PBA PANEL(RS2*31)
∙∙∙∙∙∙∙∙∙
DA41-00235B
TRANS DC(115V/60Hz)
∙∙∙∙∙∙∙
DA26-00022B
TRANS DC(220V/50,60Hz)
∙∙∙∙∙
DA26-00022C
TRANS DC(127V/60Hz)
∙∙∙∙∙∙∙
DA26-00022D
SENSOR(DEF SENSOR)
∙∙∙∙∙∙
DA32-00006D
SENSOR(F SENSOR)
∙∙∙∙∙∙∙∙
DA32-00006D
SENSOR(R SENSOR)
∙∙∙∙∙∙∙∙
DA32-00006B
SENSOR(ICE MAKER SENSOR)
∙
DA32-10108B
RELAY
∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙
DA35-10013Q
OVERLOADED REALY
∙∙∙∙∙∙∙
DA35-10013D
RUN CAPACITOR(12 ßfi)
∙∙∙∙∙∙∙
2501-001045
FAN MOTOR(FREEZER)
∙∙∙∙∙∙
DA31-00003W
FAN MOTOR(UNIT)
∙∙∙∙∙∙∙∙∙∙
DA31-00103A
4. Specifications
Compressor
Dryer
Electric box
Sub-Condenser
ELECTRICAL SPECIFICATIONS
Freezer
Refrigerator
NO LOAD PERFORMANCE
REFRIGERATION SYSTEM
INSTALLATION
MODELS
REPLACEMENT PARTS
7