54
TROUBLESHOOTING
1) Forced Operation Function
1-1) When the Power Cool or Power Freezer button is pressed once during the Test mode, “FF” lights up on the Display Panel
indicating that it is in the Forced Operation.
At this time, it starts alarming with “Beep” sounds.
1-2) When the Forced Operation is selected, the compressor starts without a 7-minute delay in any operation mode.
At this time, when it is in a Defrost mode, it stops defrosting and the Forced Operation begins.
(If the Forced Operation begins as soon as the compressor stops, it may cause the overload. So, take care when entering
into the Forced Operation.)
1-3) When the Forced Operation is selected,
RR*
: the compressor and the Fan operate for 10 minutes without stopping and it operates with Max(1°C ) setting for the
following 48 hours.
RZ*
: the compressor and the Fan operate for 24hour without stopping and it operates with Max(-23°C / -8℉ ) setting for
the following 24 hours.
1-4) When the Forced Operation is selected, the Fridge room is set to (RR* : 1°C, RZ* : -23°C / -8℉) automatically.
1-5) During the Forced Operation, the Power (RR* : Power Cool, RZ*: Power Freezer) function does not work.
When the Power function is selected, its electric icon automatically goes off in 10 seconds.
1-6) To cancel the Forced Operation in the middle of the Test function, turn off the power and turn it on again, or select the
Test Cancellation mode.
1-7) The alarm sound during the Forced Operation (in intervals of 0.5 second On and Off) keeps on until the Forced Operation
completes and there is no cancellation function.
2) Forced Defrost Function
2-1) When the Power Cool or Power Freezer button is pressed once more at the Forced Operation (F), “Fd” lights up on the
Display Panel and the Forced Operation is cancelled and the Fridge compartment starts defrosting.
2-2) At this time, “Beep” sound alarms for 3 seconds. And then, its alarm sound repeats 0.75 second On and 0.25 sec ond Off
which keeps on until the Forced R-Defrost finishes.
3) Test Cancellation Mode
3-1) While it is defrosting, put the Display Panel to the Test Mode and press the Power Cool or Power Freezer button once
more. Then, the Defrost mode will be cancelled and it goes to the normal operation mode.
Or, turn off the unit and turn it on to cancel the Test function.