53
4. TROUBLESHOOTING
Model Name
Display
RR35H6*
RR34H6*
RZ32R*
RR39T7*
RZ32T7*
RZ11M7*
[External Display]
①
Press for 6 seconds
②
Press while the
Display blink for 4
seconds
[Internal Display]
①
Press for 6 seconds
②
Press while the
Display blink for 4
seconds
1) During the normal operation, press the Fridge Key + Power Cool buttons at the same time for 6 seconds. Then, the entire
Display Panel will blink at intervals of 0.5 second for 4 seconds.
2) Before this 4-second blinking time finishes, release the Power Cool or F Power Freezer or Temp + Power
Freezer buttons and press the Power Cool or Power Freezer button.
Then, the entire Display Panel goes off and the Test mode ( Forced Operation / Defrost Mode) starts.
3) Each time the Test button is pressed, the Test function changes in sequence of Forced Operation (FF) → Forced Defrost (Fd)
→ Cancellation (Normal Operation). To cancel the Test function during the Test mode, it is recommended turning off the
power and turn it on again.
4-1) Test Function (Forced Operation & Defrost)