15
Test function is to check the product, PCB, process control and maintenance.
After the product function determined by selecting the test switch, you must re-electrify the
appliance to run the self-diagonisis function.
A.Forced Function
1) If you press the Refrigerating Temperature key and the Freeze Temperature key up to 5 minutes
at the same time, the compactor will start running with the display board highlighting
FF
.
2) If the Forced Function is selected, the compactor will start running without 5 minutes' time delay.
Defrost operation will stop if the appliance is at the state of defrosting.
3) If the forced function is selected, the compactor will keep running for 24 hours. But the
refrigerating temperature may be adjusted by pressing the Refrigerating Temperature key.
B.Forced Defrost
1) If you press the Refrigerating Temperature key and the Freeze Temperature key up to 5 minutes
simutaneously at forced startup state, the compactor will stop running and step into the forced
defrost state with the display board highlighting
Fd
.
2) If the evaporator sensor's temperature is higher than -5
under the forced defrost state, the
heater will fail to work and the compactor will resumes after the end of time-delay.
A.Compactor Protective Function
1) Restart is not allowed within 5 minutes after the stop of the compactor.
2) For forced startup, the compactor may start working without 5 minutes' time-delay by pressing
the Forced Startup button.
3) When electrifying or switching on the power, this function will start working after 3 minutes'
defrost heating.
4) When opening the refrigerating door, the fan motor will stop running and the air door is closed.
A.Opening Alarm and Illuminator
1) Opening of the refrigerating door for 2 minutes will incur Buzzer (Ding).
2) The alarm will stop with light off after 2 minutes
3) If the door is closed, the alerm will stop at once.
5-4 Test Function
C. Test Quitting
1) If you press the Refrigerating Temperature key and the Freeze Temperature key up to 5 minutes
at the same time under forced defrost state, the forced defrost function will come to a sudden end.
The refrigerator will reset and
Fd
disappear.
5-5 Other Controlling Functions
5-6 Opening Alarm and Refrigerating Compartment Illuminating Control
A. Self-diagnosis
1) The temperature sensor is considered malfunctional if its temperature go beyond -50
~ +85
.
If the core chip input voltage exceeds 0.5V~4.5V, it will be deemed as short circuit or open circuit.
5-7 Self-diagnosis
Summary of Contents for RL33EBMS
Page 12: ...11 fan leaf fan motor Evaporator air out loop air loop air 4 5 Cold Air Cycle ...
Page 27: ...26 8 PART BREAKDOWN LIST 8 1 Door ...
Page 28: ...27 No Part number Description Q ty Spec Remark ...
Page 29: ...26 8 2 Freeze Compartment ...
Page 31: ...30 8 3 Refrigerating Compartment ...
Page 32: ...31 No Part number Description Q ty Spec Remark 9 1 9 2 12 1 12 2 12 3 ...
Page 33: ...32 C C 8 4 General Assembly ...
Page 35: ...34 No Part number Description Q ty Spec Remark ...
Page 43: ......