Chapter 1 Before Installation
RFD01F Series Installation Manual v1.0
3
© Samsung Proprietary and Confidential
Specifications
The table below lists the main specifications of the RFD01F-26A.
Table 1. Specifications
Item
RRU
Air technology
FDD LTE
Operating Frequency
DL: 862~869MHz (7 MHz)
UL: 817~824 MHz(7MHz)
Channel Bandwidth
1.23 MHz(CDMA), 3/5 MHz (LTE, Scalable BW)
RF Power per sector
40 W
×
2 T
CDU-RU interface
CPRI (2.5 Gbps optic 2 ports, 20 km)
Input Voltage
-48 V DC (-38 ~ -57V DC)
Dimension (in./mm)
12.60/320(W) × 7.68/195(D)
×
12.60/320(H)
Weight
Under 22 kg
Operating Temperature
(Ambient)
-40°C ~ 55°C
Operating Humidity
5~100 %RH.
Ingress Protection
Rating
IP65
Salt Fog / Salt Spray
Telcordia GR-487-CORE, Section 3.38.1
Seismic Specification
Telcordia GR-63-CORE,
Earthquake (Zone 4) (Section 4.4.1)
Office Vibration (Section 4.4.4)
Transportation Vibration (Section 4.4.5)
Wind Resistance
Telcordia GR-487-CORE, Section 3.34
EMC
FCC Title 47 CFR Part 15
Surge Protection
DC : ± 20kA (Line to Line, Line to PE)
RET : ± 3kA (All core to PE)
ANT : ± 20kA (Core to PE)
ESD
Contact Discharge : ± 8kV
Air Discharge : ± 15kV
Safety
UL 60950-1 2nd Ed.
RF
FCC Title 47 CFR Part 90
Health
OET Bulletin 65
Cautions for Installation
Observe the following safety instructions when installing the system:
Installation shall be in accordance with the applicable local electric codes.
The equipment shall be located in restricted access locations.