background image

Model : RF265AA**, RF265AB**, 

RF265AC** 

nominal

 

vo
lta

ge

s

 

lis

ted

CN73 A/C 

Loa

d

 

120v

a

c

7-(CN70

-1

) Ice Maker 

Valv

e (Prp-Red)

CN71 

120v

a

c

1-(CN70

-1

) R 
Lamps (Blu-Red)

3-(CN70

-1

) F 
Lamp 

(Prp-Red)

5 Common 


(Gry)

7-(CN70

-1

) Comp 

(S/Blu-Red

)

9 Heate

r Common 

(Org)

CN70 

120v

a

c

1 Common 

Line 

L (Red)

5-(CN71

-5

) French Heate

r (Yel-Gry)

7-(CN71

-9

) R 
Defrost (Wht-Org)

9-(CN71

-9

) F 
Defrost (Brn-Org)

CN91 

Pantry Room Damper

1-2 Damper 

Heater (Blk-Brn) 

12v

dc

3-4 Damper 

Motor 

(Wht-Blu)

5-6 Damper 

Motor 

(Yel-Red)

CN10 Low 

Volt 

Pwr

1-3 

5VDC

(Red-Blk)

5-3 

12 VDC 

(Yel-Blk)

CN78

7,8 Pantry 

Disp

9-11

 (Blu-Wht) 

12v

dc 

10-1

1

 Sw

input (Prp-Wht) 

5v
dc 

CN50 Display

4-6 (Org-Pnk) 

 

13v

dc

5-6 (Yel-Pnk) 

 

5v
dc

CN32 Senso

r

1-4 Ambient 

Senso

r (Wht-Wht) 

1.2~2

 v

d

c

CN90 -

Ice 
Maker

1-2 

Eject Motor (Red-Blk) 

12v

dc

4-3 Ice 

Senso

r (Wht-Wht) 

2.3~3.

3

v

dc

5-8 

Test Switch (Gry

-S/Blu)

6-8 

+5v

d

(Blu)

7-8 Hall 

IC 
Out 

(Prp-S/Blu)

: GND (S/Blu)

CN30 Senso

rs & 

Switches

1-5 Freezer Dr 

Sw 

(Blk-Gry)

2-(CN50

-7

) R Door 

Sw 

 (Prp-Gry

)

3-(CN75

-1

) F 
Senso

r (Red-Gry) 

 

3.5~4.2

v

dc

4-(CN75

-1

) F 
Def 

Senso

r (Org-Gry

 

2.3~4

.2

v

dc

6

-(

C

N

7

5-

1)

 R
 Se
n

s

or

 (

W
h

t-

G

ry)

  

2.4~2

.8

v

dc

7-(CN75

-1

) R 
Def 

Senso

r (S/Blu-Gry

 

2~4.2v

dc

8-9 Pantry 

Senso

r (W/Blk-

Gry) 

 

2.6~2

.8

v

dc

CN75 

F, R, 

C Fans

2-1 F 

Fan 

(Yel-Gry) 

7~11

v

d

c

3-1 R 

Fan 

(Org-Gry

7~11v

dc

4-1 C 

Fan 

(S/Blu-Gry

7~11

v

d

c

5 F 

Fan FG 

(Blk)

6 R 

Fan 

FG(Brn)

7 C 

Fan 

FG(Red)

 

 

4

Summary of Contents for RF265AA**/XAA

Page 1: ...s simultaneously for 8 12 seconds No sound when both buttons are pressed at the same time until the display quits blinking Release the buttons and read Fault Codes This will also cancel the Fault Mode created by self diagnosis at power up Forced Mode Press the Pwr Freeze Fridge buttons simultaneously for 8 12 seconds No sound when both buttons are pressed at the same time until the display beeps a...

Page 2: ...it is lower than 1 5Ԭ for more than 5 minutes it will do a harvest with or without ice in the tray then fill with water 58 minutes after water is supplied to the Ice Tray the Ice Maker Sensor temperature will be checked When the Ice Maker Sensor maintains lower than 1 5Ԭ for 5 minutes it completes the harvest if the ice bin is not sensed as full Filling the tray After the water fill is completed t...

Page 3: ...nsor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor between 4 5V 1 0V F SENSOR Freezer Compartment Sensor Error open or short circuit connector failure Cause is also a temperature reading 122 or 58 F The voltage at MAIN PCB Sensor between 4 5V 1 0V F DEF SENSOR Freezer Room Defrost Sensor Error open or short circuit conn...

Page 4: ... 5 3 12 VDC Yel Blk CN78 7 8 Pantry Disp 9 11 Blu Wht 12vdc 10 11 Sw input Prp Wht 5vdc CN50 Display 4 6 Org Pnk 13vdc 5 6 Yel Pnk 5vdc CN32 Sensor 1 4 Ambient Sensor Wht Wht 1 2 2 vdc CN90 Ice Maker 1 2 Eject Motor Red Blk 12 4 3 Ice Sensor Wht Wht 2 3 5 8 Test Switch Gry S Blu 6 8 5vdc Blu 7 8 Hall IC Out Prp S Blu 8 GND S Blu CN30 Sensors Switches 1 5 Freezer Dr Sw Blk Gry 2 CN50 7 R Door Sw Pr...

Page 5: ...e resistance Ohm DISPLAY operating part PANTRY DISPLAY operating part ICE MAKER operating part SWITCH SENSOR part SMPS power part PANTRY ROOM DAMPER operating part FAN MOTOR operating part AC load operating part HEATER COMP ETC AC INPUT AC INPUT AC INPUT AC INPUT AC INPUT 240 120 10 10 55 220 110 441 1323 5290 1323 5290 55 220 102 407 1323 5290 RF265AA XAA RF265AB XAA RF265AC XAA 5 ...

Reviews: