40
Temp Control &Operation Functions
11-14) Power Compensation Function
It is the initial Sensor Error Display. Hold
on the Super Freeze and the Super Cool
buttons for 3 seconds and take off the
fingers. Then, press the Fridge button.
1) During the normal operation,when the Super Freeze and the Super Cool buttons are pressed for 3 seconds
at the same time, the Freezer and the Fridge temp LEDs will blink for 2 seconds at the interval of 0.5 second.
2) At this time, when pressing the Fridge button (“Ding-Dong “ goes off)after taking off the fingers from the
Super Freeze and the Super Cool buttons, it will be changed to the Load Status Display Mode.
3) The Load Status Display Mode only shows the status of the load operation command from MICOM.
MICOM sends out command signals. So, it does not mean the related components are in operation. For
example, even though it shows that a load is operating,it is not operating due to the load defect or the PCB
relay defect.It can be applied to A/S.
4) The Load Status Display function maintains for 30 seconds and it goes back to the normal operation.
OTHERS
LOAD
R-FAN
R-DEFROST HEATER
COMPRESSOR
F-FAN
F-DEFROST HEATER
INITIAL START MODE
OVERLOAD MODE
LOW TEMP MODE
R-LAMP
F-LAMP
EXIHIBITION MODE
R-Room second digit "a"
R-Room second digit "c"
F-Room second digit "a"
F-Room second digit "b"
F-Room second digit "b"
R-Room second digit "b"
R-Room second digit "e"
R-Room second digit "f"
F-Room first digit "b"
F-Room first digit "a"
R-Room second digit "g"
DISPLAY
- Self Diagnosis Check List