English 9
Ins
talling the hob
WARNING
If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
01
02
03
04
06
05
L
N
1N~ (32A)
01
220-240 V~
04
Blue
02
Black
05
Gray
03
Brown
06
Green/Yellow
01
02
03
04
05
07
06
L1
L2
N
2N~ (16A): Separate the 2-phase wires
(L1 and L2) before connection.
01
220-240 V~
05
Blue
02
380-415 V~
06
Gray
03
Black
07
Green/Yellow
04
Brown
01
04
02
03
05
06
07
L1 N1
L2 N2
2 x 1N~ (16A): Separate the wires before
connection.
01
220-240 V~
05
Brown
02
Black
06
Gray
03
Blue
07
Green/Yellow
04
220-240 V~
WARNING
For correct supply connection, follow the wiring diagram attached near the terminals.
Installing into the countertop
A
A.
Serial number
NOTE
Make a note of the serial number on the
appliance rating label prior to installation.
This number will be required in the case
of requests for service and is no longer
accessible after installation, as it is on the
original rating plate on the upperside or
underside of the appliance.
NOTE
•
Pay special attention to the minimum space and clearance requirements.
•
The bottom of the hob is equipped with a fan. If there is a drawer under the
hob it should not be used to store small objects or paper, since they could
damage the fan or interfere with the cooling if they are sucked into it.