38
3. Disassembly and Reassembly
3-23 Replacing the Assy Valve Safety
Parts
([SODQDWLRQ3KRWR
([SODQDWLRQ
Assy Valve
Safety
WIRES
8.
Install the new ASSY VALVE
SAFETY from the back wall of the
warming drawer with 4 screws.
9.
Reconnect gas lines to the ASSY
VALVE SAFETY .
NOTE:
Check
DOOJDVOLQHVDQG¿WWLQJV
for leaks before operation.
WARNING
Cross-wiring the wires to the gas
FRQWUROYDOYHFUHDWHVDQH[SORVLRQ
hazard that can result in death,
SHUVRQDOLQMXU\DQGRUSURSHUW\
and product damage.
10.
Reconnect wire connectors in their
original positions.