5-10 Proximity Sensor Adjustment (ADJ_08)
<How to adjust>
1. Change the setting on the tester mode as below.
- TEST MODE : Left → OK → Right → Ev + OK button at the same time.
- 3. Select ADJUSTMENT CONTROL.
- (2) LINE PROCESS STEP value is 08.
- (3) LINE PROCESS MARK value is 07.
2. Insert the SD card to the camera which contained adjustment data.
3. The distance between eyepiece lens and camera is 4.5cm
4. After turning on the camera, it will be start automatically.
5. After turning on the camera, it will be start automatically.
<Adjustment Result>
You can see the adjustment result by using Log File saved on the memory card. You can also confirm the
ADJUSTMENT RESULT on the Tester mode.
■
To adjust the distance of EVF perceive sensor.