Adjustment
5-9 Internal Strobe, AWB Strobe, AF auxiliary light Test (ADJ_07)
<How to adjust>
1. Combine the lens of 30mm to the camera, then located on the Dark Room(Box).
2. The distance between Gray chart(18%) and camera is 80cm
3. Change the setting on the tester mode as below.
- TEST MODE : Left → OK → Right → Ev + OK button at the same time.
- 3. Select ADJUSTMENT CONTROL.
- (2) LINE PROCESS STEP value is 07.
- (3) LINE PROCESS MARK value is 06.
4. Insert the SD card to the camera which contained adjustment data.
5. After turning on the camera, it will be start automatically.
6. After completing the adjustment, camera turned off automatically.
<Adjustment Result>
You can see the adjustment result by using Log File saved on the memory card. You can also confirm the
ADJUSTMENT RESULT on the Tester mode.
■
Adjust the CMOS characteristics. (AWB Low Level)