background image

6

English

Tools and Parts

Removing the packaging

CAUTION

Remove the carton carefully. Wear gloves to protect against sharp edges.

  WARNING

 

Remove the protective film covering the product before putting into 

operation.

Parts supplied

 

Hood assembly with blower and LED lamps already installed.

 

Hardware bag with:

Part

Qty

Part

Qty

3.5 x 9.5 mm

2

Torx

®†

 T10 adapter

1

5 x 45 mm

2

4.5x13 mm

4

8 x 45 mm

2

3

1

4

" x 10" (8.3 x 25.4 cm)

rectangular damper

1

Tools/Materials required

 

Level

 

Drill with 

1

8

” (3 mm), ½” (13 mm) and 1¼” (30 mm) drill bits

 

Pencil

 

Wire stripper or utility knife

 

Tape measure or ruler

 

Pliers

 

Caulking gun and weatherproof caulking compound

 

Saber or keyhole saw 

 

Metal snips

 

Screwdrivers: 

 

#2 Phillips

 

Flat - blade 

Parts needed

 

Home power supply cable

 

½” (12.7 mm) UL listed or CSA approved strain relief

 

3 UL listed wire connectors

For 7" (17.8 cm) round vented installations

 

7" (17.8 cm) round mental vent system with wall or roof cap

 

Vent clamps

For 3¼" x 10" (8.3 x 25.4 cm) rectangular vented installations

 

3¼" x 10" (8.3 x 25.4 cm) rectangular metal vent system with wall or 

roof cap.

Dimensions and Clearances

A

B

E

I

F

G

H

C

D

NK30B3500US/AA

A

30″ (76 cm)

B

18

7

8

″ (48 cm)

C

4

15

16

″ (12.5 cm)

D

14½″ (36.7 cm)

E

2″ (5.2 cm)

F

27

15

/

16

″ (

70.9 cm)

G

9″ (22.9 cm)

H

1½″ (3.8 cm)

I

1″ (2.5 cm)

Installation Requirements

Installation Requirements

Summary of Contents for NK30B3500US

Page 1: ...Range Hood Hotte de la cuisine Campana de cocina LIB0175247 ...

Page 2: ...Venting Methods 7 Installation Instructions 7 Prepare the location 8 Prepare Range Hood 8 Mark Hole Locations 9 Mark and Cut Vent Opening 9 Drill Electrical Opening 10 Prepare Range Hood Vents 10 Attach Vent Damper or Transition 10 Mounting the Hood 11 Connect Vent System 11 Electrical Connection 11 Completing the installation 11 Range Hood Use and Care 12 Range Hood Description 12 Range Hood Cont...

Page 3: ...rence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception...

Page 4: ...FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn the hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé Clean ventilating fans frequently Grease should not be allowed to accumulate on the fan or filter Use pr...

Page 5: ... clamps to seal all joints in the vent system The vent system must have a damper If the roof or wall cap has a damper do not use the damper supplied with the range hood Use caulking to seal the exterior wall or roof opening around the cap The size of the vent should be uniform Venting Methods To use the hood s top outlet to vent your hood a 3 x 10 8 3 x 25 4 cm rectangular with a maximum vent leng...

Page 6: ... utility knife Tape measure or ruler Pliers Caulking gun and weatherproof caulking compound Saber or keyhole saw Metal snips Screwdrivers 2 Phillips Flat blade Parts needed Home power supply cable 12 7 mm UL listed or CSA approved strain relief 3 UL listed wire connectors For 7 17 8 cm round vented installations 7 17 8 cm round mental vent system with wall or roof cap Vent clamps For 3 x 10 8 3 x ...

Page 7: ...e 31 4 x 10 8 3 x 25 4 cm rectangular with a maximum vent length of 35 ft 10 7 m or 7 17 8 cm or larger round vent with a maximum length of 50 ft 15 2 m for vent system Use the diagram or the hood as a template and mark the locations for the ductwork electrical wiring and keyhole screw slots D C CL E FRONT OF THE HOOD WALL B A 3 95 cm 11 2 7 17 8 cm 8 3 cm 10 25 4 cm 31 4 A 30 76 cm B 187 8 48 cm ...

Page 8: ...nd then release the brackets on the front 4 Using 2 or more people lift the range hood up under cabinet and determine final location by centering beneath cabinet Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood A NOTE Mark the thin area of the slot On the back wall mark the holes for the security screws B Set range hood aside on a covered surface A A K...

Page 9: ...erside of the cabinet Drill a 7 8 2 2 cm diameter hole B through the rear wall at this point B A 7 8 2 2 cm A 8 2 5 21 3cm Mark and Cut Vent Opening For a non vented recirculating installation skip Mark and Cut Vent Opening step For 3 x 10 8 3 x 25 4 cm Rectangular Vent System Roof Venting To make a 4 x 10 10 16 cm x 26 7 cm rectangular cutout on the underside of cabinet top and bottom 1 Mark line...

Page 10: ...trical Opening 1 Using a 1 3 cm drill bit drill the hole in the dot marked previously at the electrical strain relief Prepare Range Hood Vents A B C D E Install Strain Relief 1 Install a UL listed CSA approved 13 mm strain relief A For non vented Recirculating Installations Remove the 2 T10 Torx screws and remove the top front rectangular vent cover E Go to Electrical Connection step When used in ...

Page 11: ...System 1 Connect the vent work to the range hood 2 Seal joints with vent clamps or duct tape to make secure and airtight 3 Check that the backdraft dampers work properly Electrical Connection WARNING ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING REPLACE ALL PARTS AND PANELS BEFORE OPERATING FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK A B C D E F G A White wires B Black wir...

Page 12: ...ded replace the metal grease filter When washed in a dishwasher the grease filter may discolor slightly but this does not affect its filtering capacity To replace metal grease filter 1 Remove the filter by pulling the latch toward the back of the range hood and using a Torx T10 adapter remove the screw from the filter retainer replace the filter and place the screw back Metal grease filter is not ...

Page 13: ...fore wiring 1 MOUNT THE SWITCH BOX Install a 3 deepsingle gang switch box 2 ATTACH THE POWER CABLE Clamp wiring to the switch box and unit using an appropriate clamp Provide 6 leads inside the box and fan for easier wiring 3 CONNECT THE WIRING General instructions Make sure both the switch box and the appliance are properly grounded Make sure the ground wire is securely fastened to the control s g...

Page 14: ...ystems utilities services parts supplies accessories applications installations repairs external wiring or connectors not supplied or authorized by SAMSUNG which damage this product or result in service problems incorrect electrical line voltage fluctuations and surges customer adjustments and failure to follow operating instructions cleaning maintenance and environmental instructions that are cov...

Page 15: ...llations repairs external wiring or connectors not supplied or authorized by SAMSUNG which damage this product or result in service problems incorrect electrical line voltage fluctuations and surges customer adjustments and failure to follow operating instructions cleaning maintenance and environmental instructions that are covered and prescribed in the instruction book problems caused by pest inf...

Reviews: