background image

English

13

Range Hood Use and Care

Range Hood Use and Care

Range Hood for ADA Compliance

Range hoods can be installed to comply with Sections 308 and 309 of 

ADA Guidelines, when used with appropriately mounted controls installed 

at 15” (38.1 cm) to 40” (101.6 cm) above the floor and control access 

does not require reaching over a cooking appliance.

This range hood model NK30B3500US/AA can work in an ADA Compliant 

situation when the range hood is wired to operate from a dedicated, 

standard electrical wall switch. To facilitate this application, share the 

information on the following pages with your electrician when preparing 

for the installation.

NOTE

All the models can be controlled by only one remote switch (The switch 

activates or deactivates the motor and the light of the hood).

  WARNING

All electrical work must be done in accordance with local codes, 

ordinances, or the national electrical code as applicable. For safety, this 

product must be installed in a grounded switch box. The electrical wiring 

installation must be done by a qualified technician. 

  WARNING

Electrical Shock Hazard
Turn off power at the circuit breaker panel or fuse box before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.

(L, ground)

D

E

B

C

F

G

H

E

A

(N, ground)

POWER SUPPLY HOME

G

A. Range Hood Cable
B. UL listed wire connector
C. White wires (N)
D. Black wires (L)
E. Green (or bare) and
    yellow-green ground

F. UL listed switch
G. Home power supply cable
H. Deep single gang switch box

  WARNING

To avoid fire or electrical shock, turn off power at the circuit breaker
panel or fuse box. Confirm that the power is off before wiring.

1. 

MOUNT THE SWITCH BOX . Install a 3½” deepsingle gang switch 

box 

2. 

ATTACH THE POWER CABLE. Clamp wiring to the switch box and 

unit using an appropriate clamp. Provide 6” leads inside the box and 

fan for easier wiring.

3. 

CONNECT THE WIRING. General instructions: 

 

Make sure both the switch box and the appliance are properly 

grounded.

 

Make sure the ground wire is securely fastened to the control’s 

ground screw. Tighten the ground screw.

 

Use proper wire nut sizes for the number and size of the wires.

 

For push-in and screw terminals: Use min. #14 AWG solid copper 

wire only.

 

Tighten the screw terminals.

 

Make electrical connections following the appropriate diagram.

For supply connection

use wires suitable 

for at least 75° (167°F)

M

S15

8uF

YEL

WHT (SPEED 1)

YEL (LAMP)

BLK (SPEED 3)

BLK (LINE)

BWN (SPEED 1)

BWN

BWN

RED (SPEED 2)

GREY (SPEED 3)

GR

Y (SPEED 2)

RED (COMMON)

WHT 

N

1

2

3

4

5

6

LED

LED

GND

YEL/GRE

WHT

WHT

BLK

BLU

BLK

RED

MOTOR CHARACTERISTICS

POWER SUPPLY       

FREQUENCY                 

AMPERAGE 

 WATTAGE RATING   

120 VAC

60 Hz

0,9 ±10% A  

110 w

MOTOR RESISTANCE

RED - BROWN

 RED - BLACK  

 RED - GREY 

RED - WHITE  

27.5

55.7

86.8 

117.7

SEL0168627

>85

-1.5

+1.5

-1

+1

0÷85

27/10/20

Luis Salazar

29/04/20

PRINTING AREA

(101.6X101.6mm)

RELEASED

* DO NOT PRINT DASHED LINE

Schema elettrico / Wiring diagram

Carta metallizzata 101.6x101.6 / Metallic Sticky Paper x

SEL0168627

Nero / Black

3:2

PIRITE SAMSUNG

PUSH BUTTON SWITCH

 3        2       1        L        L      La     M

BLU

PUSH BUTTON SWITCH OPERATION

FUNCTION 

OFF

LAMPS

LOW SPEED

MED SPEED

HIGH SPEED

POSITION

NO CONNECTION

(L-4)

(L-1)

(L-2)

(L-3)

BLUE- YELLOW

BROWN- WHITE

BROWN- RED 

BROWN- BLACK 

INPUT: 120VAC

+

-

OUTPUT:700mA(2-15VDC)

LED DRIVER

BK

For ADA compliance add these

elements during the installation

Remote Switch 

L

BK

L

4. 

MOUNT THE CONTROL IN THE SWITCH BOX. Tuck wires into 

the switch box and fasten the control to the box using the attached 

screws.

5. 

ATTACH THE SWITCH PLATE. Fasten the switch plate to the control 

using the short screws from the parts bag.

Summary of Contents for NK30B3500US

Page 1: ...Range Hood Hotte de la cuisine Campana de cocina LIB0175247 ...

Page 2: ...Venting Methods 7 Installation Instructions 7 Prepare the location 8 Prepare Range Hood 8 Mark Hole Locations 9 Mark and Cut Vent Opening 9 Drill Electrical Opening 10 Prepare Range Hood Vents 10 Attach Vent Damper or Transition 10 Mounting the Hood 11 Connect Vent System 11 Electrical Connection 11 Completing the installation 11 Range Hood Use and Care 12 Range Hood Description 12 Range Hood Cont...

Page 3: ...rence in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception...

Page 4: ...FIRE Never leave surface units unattended at high settings Boilovers cause smoking and greasy spillovers that may ignite Heat oils slowly on low or medium settings Always turn the hood ON when cooking at high heat or when flambeing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flambé Clean ventilating fans frequently Grease should not be allowed to accumulate on the fan or filter Use pr...

Page 5: ... clamps to seal all joints in the vent system The vent system must have a damper If the roof or wall cap has a damper do not use the damper supplied with the range hood Use caulking to seal the exterior wall or roof opening around the cap The size of the vent should be uniform Venting Methods To use the hood s top outlet to vent your hood a 3 x 10 8 3 x 25 4 cm rectangular with a maximum vent leng...

Page 6: ... utility knife Tape measure or ruler Pliers Caulking gun and weatherproof caulking compound Saber or keyhole saw Metal snips Screwdrivers 2 Phillips Flat blade Parts needed Home power supply cable 12 7 mm UL listed or CSA approved strain relief 3 UL listed wire connectors For 7 17 8 cm round vented installations 7 17 8 cm round mental vent system with wall or roof cap Vent clamps For 3 x 10 8 3 x ...

Page 7: ...e 31 4 x 10 8 3 x 25 4 cm rectangular with a maximum vent length of 35 ft 10 7 m or 7 17 8 cm or larger round vent with a maximum length of 50 ft 15 2 m for vent system Use the diagram or the hood as a template and mark the locations for the ductwork electrical wiring and keyhole screw slots D C CL E FRONT OF THE HOOD WALL B A 3 95 cm 11 2 7 17 8 cm 8 3 cm 10 25 4 cm 31 4 A 30 76 cm B 187 8 48 cm ...

Page 8: ...nd then release the brackets on the front 4 Using 2 or more people lift the range hood up under cabinet and determine final location by centering beneath cabinet Mark on the underside of cabinet the location of the 4 keyhole mounting slots on the range hood A NOTE Mark the thin area of the slot On the back wall mark the holes for the security screws B Set range hood aside on a covered surface A A K...

Page 9: ...erside of the cabinet Drill a 7 8 2 2 cm diameter hole B through the rear wall at this point B A 7 8 2 2 cm A 8 2 5 21 3cm Mark and Cut Vent Opening For a non vented recirculating installation skip Mark and Cut Vent Opening step For 3 x 10 8 3 x 25 4 cm Rectangular Vent System Roof Venting To make a 4 x 10 10 16 cm x 26 7 cm rectangular cutout on the underside of cabinet top and bottom 1 Mark line...

Page 10: ...trical Opening 1 Using a 1 3 cm drill bit drill the hole in the dot marked previously at the electrical strain relief Prepare Range Hood Vents A B C D E Install Strain Relief 1 Install a UL listed CSA approved 13 mm strain relief A For non vented Recirculating Installations Remove the 2 T10 Torx screws and remove the top front rectangular vent cover E Go to Electrical Connection step When used in ...

Page 11: ...System 1 Connect the vent work to the range hood 2 Seal joints with vent clamps or duct tape to make secure and airtight 3 Check that the backdraft dampers work properly Electrical Connection WARNING ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING REPLACE ALL PARTS AND PANELS BEFORE OPERATING FAILURE TO DO SO CAN RESULT IN DEATH OR ELECTRICAL SHOCK A B C D E F G A White wires B Black wir...

Page 12: ...ded replace the metal grease filter When washed in a dishwasher the grease filter may discolor slightly but this does not affect its filtering capacity To replace metal grease filter 1 Remove the filter by pulling the latch toward the back of the range hood and using a Torx T10 adapter remove the screw from the filter retainer replace the filter and place the screw back Metal grease filter is not ...

Page 13: ...fore wiring 1 MOUNT THE SWITCH BOX Install a 3 deepsingle gang switch box 2 ATTACH THE POWER CABLE Clamp wiring to the switch box and unit using an appropriate clamp Provide 6 leads inside the box and fan for easier wiring 3 CONNECT THE WIRING General instructions Make sure both the switch box and the appliance are properly grounded Make sure the ground wire is securely fastened to the control s g...

Page 14: ...ystems utilities services parts supplies accessories applications installations repairs external wiring or connectors not supplied or authorized by SAMSUNG which damage this product or result in service problems incorrect electrical line voltage fluctuations and surges customer adjustments and failure to follow operating instructions cleaning maintenance and environmental instructions that are cov...

Page 15: ...llations repairs external wiring or connectors not supplied or authorized by SAMSUNG which damage this product or result in service problems incorrect electrical line voltage fluctuations and surges customer adjustments and failure to follow operating instructions cleaning maintenance and environmental instructions that are covered and prescribed in the instruction book problems caused by pest inf...

Reviews: