12
3. Disassembly and Reassembly
3-2 Removing PCB-Sub & L.V.Trans
WARNING
ELECTRICAL SHOCK HAZARD
Disconnect power before servicing the range. Replace all panels before operating range. Failure to do so
can result in death or electrical shock.
PRECAUTION
When you work on the electric range, be careful when handling the sheet metal parts. Sharp edges may
be present, and you can cut yourself if you are not careful.
Parts
Explanation Photo
Explanation
PCB-Sub &
L.V.Trans
PCB-Main
1.
Turn off the electrical supply
going to the range.
2.
Pull the range away from the
wall so that you can access the
rear panel.
3.
Remove Cover-Back Main Wire
and Cover-Back Guard Wire
(See step 4 on page 12)
4.
There are 2 PCB
¶
s (power
control board). When you
check PCB, check the proper
PCB in default mode and check
main PCB.
2 Screws
5.
To remove the control power
supply:
a) Disconnect 2 connectors.
b) Remove the two screws.
1(5$%65B$$LQGE